The thread shape factor (TSF) to evaluate the relationships between geometrical characteristics and mechanical properties of the temporary anchorage devices (TADs) has recently been introduced. This in vitro experimental study evaluated in 30 different tests with three TADs: ORTHOImplant (1.8 mm diameter and 10 mm length; 3M Unitek), Tomas (1.6 mm diameter and 10 mm length; Dentaurum), and Orthoeasy (1.7 mm diameter and 10 mm length; Forestadent). Scanning electron microscopy images were acquired for each TAD to measure the TSF; afterwards, the maximum insertion torque (MIT) was evaluated and thereafter pull-out tests on two differently designed organic bone analogs were carried out using a testing machine with a crosshead speed of 2 mm/minute being applied. One-way analysis of variance with group as factor was performed. Post hoc multiple comparisons Bonferroni test was used. Rank-transformed data were used when asymmetry of data was shown. To assess correlation between characteristics, load, and MIT, Spearman's rank correlation coefficient was used. A P-value of 0.05 was considered statistically significant. Significant direct correlations were found between TSF and depth and both load and MIT. Particularly, a correlation of 0.90 (P < 0.001) was found between depth and MIT for 2.2 mm cortical thickness. The authors conclude that MIT and maximum load values of pull-out test are statistically related to depth of the thread of the screw and to TSF.
منابع مشابه
Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملInsertion torque of orthodontic miniscrews according to changes in shape, diameter and length.
OBJECTIVE To determine the variation in the insertion torque of orthodontic miniscrews according to the screw length, diameter, and shape. MATERIALS AND METHODS The maximum insertion torque (MIT) was measured using a torque tester at a constant speed of 3 rotations per minute. Cylindrical and taper type of miniscrews (Biomaterials Korea Inc, Seoul, Korea) with different lengths, diameters, an...
متن کاملThe effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study.
The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability. In six adult male beagle dogs (12 months old), 36 orthodontic miniscrews were inserted into the mandibular buccal alveolar bone without drilling. Immediately after insertion, 24 miniscrews were loaded with 1- and 2-Ncm nickel titanium (NiTi) coil ...
متن کاملEvaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study
BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...
متن کاملHistological and fluorescence microscopic examination of the bone/implant interface in orthodontic miniscrews (Mondeal).
The temporary nature of orthodontic implants demands optimisation of size and design in order to minimise damage and risk to the patient. Slender and shorter miniscrews offer the advantage over conventional implants of easier and more ubiquitous positioning with minimised risk of injury to neighbouring anatomical structures such as tooth roots, nerves or vessels. The question is raised, however...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2013