Flexural strength of acrylic resin repairs processed by different methods: water bath, microwave energy and chemical polymerization

نویسندگان

  • João Neudenir ARIOLI FILHO
  • Luís Eduardo BUTIGNON
  • Rodrigo de Paula PEREIRA
  • Matheus Guilherme LUCAS
  • Francisco de Assis MOLLO JUNIOR
چکیده

UNLABELLED Denture fractures are common in daily practice, causing inconvenience to the patient and to the dentists. Denture repairs should have adequate strength, dimensional stability and color match, and should be easily and quickly performed as well as relatively inexpensive. OBJECTIVE The aim of this study was to evaluate the flexural strength of acrylic resin repairs processed by different methods: warm water-bath, microwave energy, and chemical polymerization. MATERIAL AND METHODS Sixty rectangular specimens (31x10x2.5 mm) were made with warm water-bath acrylic resin (Lucitone 550) and grouped (15 specimens per group) according to the resin type used to make repair procedure: 1) specimens of warm water-bath resin (Lucitone 550) without repair (control group); 2) specimens of warm water-bath resin repaired with warm water-bath; 3) specimens of warm water-bath resin repaired with microwave resin (Acron MC); 4) specimens of warm water-bath resin repaired with autopolymerized acrylic resin (Simplex). Flexural strength was measured with the three-point bending in a universal testing machine (MTS 810 Material Test System) with load cell of 100 kgf under constant speed of 5 mm/min. Data were analyzed statistically by Kruskal-Wallis test (p<0.05). RESULTS The control group showed the best result (156.04±1.82 MPa). Significant differences were found among repaired specimens and the results were decreasing as follows: group 3 (43.02±2.25 MPa), group 2 (36.21±1.20 MPa) and group 4 (6.74±0.85 MPa). CONCLUSION All repaired specimens demonstrated lower flexural strength than the control group. Repairs with autopolymerized acrylic resin showed the lowest flexural strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface roughness of acrylic resins processed by microwave energy and polished by mechanical and chemical process

Correspondence to: Célia Marisa Rizzatti-Barbosa Department of Prosthesis and Periodontology Piracicaba Dental School, State University of Campinas (UNICAMP) Avenida Limeira, 901. Areião CEP: 13414-018 Piracicaba São Paulo Brazil. Phone: 00 55 19 3412 5373 Fax: 00 55 19 3412 5218 E-mail: [email protected] Abstract The aim of this study was to evaluate the influence of polymerization metho...

متن کامل

Effect of Post-polymerization Treatments on the Flexural Strength and Vickers Hardness of Reline and Acrylic Denture Base Resins

This study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73 degrees C and 1...

متن کامل

Effect of microwave irradiation on the flexural strength and residual monomer levels of an acrylic resin repair material.

The degree of polymerization of an acrylic resin repair material, as established by residual monomer estimation, was compared using three different polymerization methods, i.e. bench-cure, hydroflask-cure and microwave irradiation cure. The repair strength of a conventional heat-polymerized resin was then assessed following repairs using each of these three methods. The lowest level of residual...

متن کامل

Flexural Strength of Acrylic Resins Polymerized by Different Cycles

Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Clássico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acryl...

متن کامل

Water sorption of heat-polymerized acrylic resins processed in mono and bimaxillary flasks.

This study evaluated water sorption in heat-polymerized acrylic resins processed in monomaxillary flasks by water bath and in bimaxillary flasks by microwave energy and water bath. Fifty heat-polymerized acrylic resin specimens were fabricated according to the 12th specification of the American Dental Association and assigned to 3 groups: group 1 was processed by water bath in monomaxillary met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2011