Reverse hybrid total hip arthroplasty
نویسندگان
چکیده
Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty Register Association (NARA) has already published 2 papers describing results of reverse hybrid THAs in different age groups. Based on data collected over 2 additional years, we wanted to perform in depth analyses of not only the reverse hybrid concept but also of the different cup/stem combinations used. Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk of revision. The main endpoint was revision for any reason. We also performed specific analyses regarding the different reasons for revision and analyses regarding the cup/stem combinations used in more than 500 cases. Results - We found a higher rate of revision for reverse hybrids than for cemented THAs, with an adjusted relative risk of revision (RR) of 1.4 (95% CI: 1.3-1.5). At 10 years, the survival rate was 94% (CI: 94-95) for cemented THAs and 92% (95% CI: 92-93) for reverse hybrids. The results for the reverse hybrid THAs were inferior to those for cemented THAs in patients aged 55 years or more (RR =1.1, CI: 1.0-1.3; p < 0.05). We found a higher rate of early revision due to periprosthetic femoral fracture for reverse hybrids than for cemented THAs in patients aged 55 years or more (RR =3.1, CI: 2.2-4.5; p < 0.001). Interpretation - Reverse hybrid THAs had a slightly higher rate of revision than cemented THAs in patients aged 55 or more. The difference in survival was mainly caused by a higher incidence of early revision due to periprosthetic femoral fracture in the reversed hybrid THAs.
منابع مشابه
Hybrid or reverse hybrid for total hip arthroplasty?
When reverse hybrid total hip arthroplasty (cemented thick all poly acetabular cup and uncemented hydroxyapatite coated femoral stem) was initiated in Turkey by this author in 1989, there was too much negative criticism.[1,2] The reason for preferring this option was earlier personal experience and the literature data.[3,4] Currently, to the author’s knowledge, there is no other orthopedic surg...
متن کاملIs reverse hybrid hip replacement the solution?
BACKGROUND AND PURPOSE Reverse hybrid hip replacement uses a cemented all-polyethylene cup and an uncemented stem. Despite increasing use of this method in Scandinavia, there has been very little documentation of results. We have therefore analyzed the results from the Norwegian Arthroplasty Register (NAR), with up to 10 years of follow-up. PATIENTS AND METHODS The NAR has been collecting dat...
متن کاملThe Corail stem as a reverse hybrid - survivorship and x-ray analysis at 10 years.
BACKGROUND The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA have been sparsely described.We report our experience of reverse hybrid THA, using the Elite plus polyethylene cemented cup together with the Corail fully hydroxyapatite-co...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملFailure rate of cemented and uncemented total hip replacements: register study of combined Nordic database of four nations.
OBJECTIVE To assess the failure rate of cemented, uncemented, hybrid, and reverse hybrid total hip replacements in patients aged 55 years or older. DESIGN Register study. SETTING Nordic Arthroplasty Register Association database (combined data from Sweden, Norway, Denmark, and Finland). PARTICIPANTS 347,899 total hip replacements performed during 1995-2011. MAIN OUTCOME MEASURES Probabi...
متن کامل