Reconstruction of optical properties of phantom and breast lesion in vivo from paraxial scanning data.

نویسندگان

  • Thomas Dierkes
  • Dirk Grosenick
  • K Thomas Moesta
  • Michael Möller
  • Peter M Schlag
  • Herbert Rinneberg
  • Simon Arridge
چکیده

We report on the reconstruction of absorption and reduced scattering coefficients of breast tissue in vivo of a patient with mastopathic disease. Distributions of times of flight of photons through the compressed breast were recorded by paraxial scanning. From data measured at four different source-detector offsets optical properties were reconstructed within the linear Rytov approximation by a fast inverse Fourier space method. Low-pass filtering in Fourier space was employed to remove excessive noise from high spatial frequency components and to reduce the computational efforts by a factor of 3, typically. The mammograms displaying reconstructed absorption and reduced scattering coefficients were compared with projection mammograms either obtained by time-window analysis of experimental data or based on average absorption and reduced scattering coefficients which were derived from measured temporal point spread functions within a simple homogeneous model. All inhomogeneities which were visible in the projection mammograms and which could be associated with specific breast tissue compartments could be correlated with inhomogeneities in the reconstructed absorption coefficient. In particular, the mastopathic disease was detected in the reconstructed absorption mammogram. In order to assess reliability of optical properties reconstructed from data obtained by paraxial scanning, corresponding phantom experiments and reconstructions of phantom optical properties were carried out. Because of the limited angular range sampled by the in vivo and phantom measurements, considerable blurring of the absorption coefficient occurs along the compression direction, compromising longitudinal resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

Collimator-detector response compensation in molecular SPECT reconstruction using STIR framework

Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT.  In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...

متن کامل

The Effect of Breast Reconstruction Prosthesis on Photon Dose Distribution in Breast Cancer Radiotherapy

Introduction: Siliconeprosthetic implants are commonlyutilizedfor tissue replacement and breast augmentation after mastectomy. On the other hand, some patients require adjuvant radiotherapy in order to preventlocal-regional recurrence and increment ofthe overall survival. In case of recurrence, the radiation oncologist might have to irradiate the prosthesis.The aim of this study was to evaluate...

متن کامل

Three-dimensional time-resolved optical tomography of a conical breast phantom.

A 32-channel time-resolved imaging device for medical optical tomography has been employed to evaluate a scheme for imaging the human female breast. The fully automated instrument and the reconstruction procedure have been tested on a conical phantom with tissue-equivalent optical properties. The imaging protocol has been designed to obviate compression of the breast and the need for coupling f...

متن کامل

Magnetic resonance-guided near-infrared tomography of the breast

The design and implementation of a multispectral, frequency-domain near infrared tomography system is outlined, which operates in a MRI magnet for utilization of MR-guided image reconstruction of tissue optical properties. Using long silica optical fiber bundles, measurements of light transmission through up to 12 cm of female breast tissue can be acquired simultaneously with MRI scans. The NIR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 11  شماره 

صفحات  -

تاریخ انتشار 2005