Analytical method for the determination of organic acids in dilute acid pretreated biomass hydrolysate by liquid chromatography-time-of-flight mass spectrometry

نویسندگان

  • Ana B Ibáñez
  • Stefan Bauer
چکیده

BACKGROUND For the development of lignocellulosic biofuels a common strategy to release hemicellulosic sugars and enhance the enzymatic digestibility of cellulose is the heat pretreatment of biomass with dilute acid. During this process, fermentation inhibitors such as 5-hydroxymethylfurfural, furfural, phenolics, and organic acids are formed and released into the so-called hydrolysate. The phenolic inhibitors have been studied fairly extensively, but fewer studies have focused on the analysis of the organic acids profile. For this purpose, a simple and fast liquid chromatography/mass spectrometry (LC/MS) method for the analysis of organic acids in the hydrolysate has been developed using an ion exchange column based on a polystyrene-divinylbenzene polymer frequently used in biofuel research. The application of the LC/MS method to a hydrolysate from Miscanthus has been evaluated. RESULTS The presented LC/MS method involving only simple sample preparation (filtration and dilution) and external calibration for the analysis of 24 organic acids present in dilute acid pretreated biomass hydrolysate is fast (12 min) and reasonably sensitive despite the small injection volume of 2 μL used. The lower limit of quantification ranged from 0.2 μg/mL to 2.9 μg/mL and the limit of detection from 0.03 μg/mL to 0.7 μg/mL. Analyte recoveries obtained from a spiked hydrolysate were in the range of 70 to 130% of the theoretical yield, except for glyoxylic acid, malic acid, and malonic acid, which showed a higher response due to signal enhancement. Relative standard deviations for the organic acids ranged from 0.4 to 9.2% (average 3.6%) for the intra-day experiment and from 2.1 to 22.8% (average 8.9%) for the inter-day (three-day) experiment. CONCLUSION We have shown that the analysis of the profile of 24 organic acids present in biomass hydrolysate can be achieved by a simple LC/MS method applying external calibration and minimal sample preparation. The organic acids eluted within only 12 min by isocratic elution, enabling high sample throughput. Repeatability (precision and accuracy) and recovery were sufficiently accurate for most of the organic acids tested, making the method suitable for their fast determination in hydrolysate. We envision that this method can be further expanded to a larger number of organic acids, including phenolic acids such as p-coumaric acid and ferulic acid and other molecules depending on the researchers' needs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia

Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014