Retention characteristics of attachment systems for implant overdentures.

نویسندگان

  • Kwok-Hung Chung
  • Cho-Yao Chung
  • David R Cagna
  • Robert J Cronin
چکیده

PURPOSE The aim of this study was to compare the retention characteristics of various overdenture attachment systems commonly used to retain overdentures to dental implants. MATERIALS AND METHODS An edentulous mandibular model was constructed incorporating 2 parallel 4.0 mm x 13 mm Branemark implants placed in the canine regions. Attachments were embedded in a metal-reinforced experimental overdenture designed to be dislodged from the model by a universal testing machine. Tensile dislodging force was applied to the overdenture at a cross-head speed of 50 mm/min. Five overdentures were constructed for each of the attachment systems. The attachments evaluated were the Hader bar & metal clip, Locator LR pink, Locator LR white, Spheroflex ball, Shiner magnet, Maxi magnet, Magnedisc magnet, ERA white, and ERA gray. Each apparatus was tested with 5 specimens per attachment system. Peak load-to-dislodgement was measured. Analysis of variance and Scheffe multiple comparison tests were applied to the data with alpha< or = 0.05 level of significance. RESULTS Peak load-to-dislodgement for all attachment systems ranged from 3.68 +/- 1.32 N to 35.24 +/- 1.99 N. Strain-at-dislodgement, calculated from stress-strain curves, ranged from 0.78 +/- 0.20% to 2.78 +/- 0.5%. The ERA gray attachment demonstrated the greatest retention, with a peak load-to-dislodgement of 35.24 +/- 1.99 N, and a relatively low strain-at-dislodgement of 1.64 +/- 0.09%. Less retention was recorded for the Locator LR white, Spheroflex ball, Hader bar & metal clip, and ERA white systems. The Locator LR pink attachment demonstrated still less retention with a load-to-dislodgement of 12.33 +/- 1.28 N. Significantly high strain-at-dislodgement was recorded for the Hader bar & metal clip and Locator nylon attachment systems. The lowest dislodging loads and strains were recorded for the Shiner magnet, Maxi magnet, and Magnedisc magnet attachments. CONCLUSIONS Results suggest that the attachment systems evaluated may be grouped into high (ERA gray), medium (Locator LR white, Spheroflex ball, Hader bar & metal clip, ERA white), low (Locator LR pink), and very low (Shiner magnet, Maxi magnet, Magnedisc magnet) retention characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

Effects of overdenture retention designs and implant orientations on load transfer characteristics.

Various approaches have been used for the retention and stabilization of implant-supported overdentures. This study examined photoelastically the simulated load transfer characteristics of a resilient cap attachment with moderately atrophied mandibular plastic models with two implant orientations. Comparison was made with overdentures supported by a splinting bar and a bar with distal resilient...

متن کامل

The Amount of Wear in Attachment of Implant-Supported Overdentures in Mandible

Background and objectives: One of the simplest and cheapest attachments for overdentures, is the ball-type attachment, however, keeping it during the first year of prosthesis delivery and after that is one of the main concerns of dentists. The present study aimed to assess the wear of matrix in overdentures attachment supported by one, two and three implants in the mandible. Materials and metho...

متن کامل

A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems.

OBJECTIVES The objective of this clinical study was to evaluate the prosthetic complications of patients with 2 to 4 implants splinted with a round bar or with 2 to 4 unsplinted implants with ball attachments during the follow-up period. METHODS A total of 26 patients were included in this study. Patients were randomly provided with a round bar or with ball attachments that were used to retai...

متن کامل

Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

A plethora of attachment systems for mandibular two-implant overdentures is currently available often without evidence-based support. Technical aspects are now parameters considered when choosing the appropriate attachment. Despite the increasing use of the Locator attachments, studies regarding their properties remain scarce. Peer reviewed articles published in English up to 2011, were identif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 2004