The Intraocular Lens as a Drug Delivery Device: In Vitro Screening of Pharmacologic Substances for the Prophylaxis of Posterior Capsule Opacification.
نویسندگان
چکیده
Purpose Numerous pharmacologic substances have been proposed for preventing posterior capsule opacification (PCO). The following trial was to compare those drugs to find more suitable options. IOL should then be modified by the pharmaceuticals as a drug-delivery device. Methods A systematic literature search was performed to identify published substances. FHL-124 was used to determine cell proliferation and toxicity using a dye reduction test (XTT). Prescreened substances showing a reduction on cell growth without being toxic were soaked into an IOL. Those IOL were tested for their effect on PCO in an anterior-segment model and the human ex vivo capsular bag model. Toxicity on a corneal endothelial cell line (CEC-SV40) was determined. Release kinetics of methotrexate from the IOL was measured. Toxicity testing in both cell lines was done in serum-free conditions. All growth assays were exposed to 10% fetal calf serum (FCS)-supplemented medium. Results The substances inhibited cell growth at the following EC50: caffeic acid phenethyl ester 1.6 ± 0.9 nM, disulfiram 359 ± 33 nM, methotrexate 98.0 ± 29.7 nM, rapamycin 70.2 ± 14.0 pM, and retinoic acid 1.1 ± 0.12 nM. All but disulfiram showed an effect in the anterior segment model when soaked into an IOL. Long-term inhibitory effects in the human capsular bag model were observed for caffeic acid phenethyl ester and methotrexate IOLs. Only methotrexate and disulfiram did not show any toxicity on endothelial cells. Methotrexate was released constantly from the hydrophilic IOL for 2 weeks. Conclusions We could identify caffeic acid phenethyl ester and methotrexate in vitro as potential candidates for IOL modification for PCO prophylaxis.
منابع مشابه
Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملPrevention of posterior capsule opacification by an intracapsular open capsule device.
PURPOSE To investigate the ability of an open capsule device to prevent posterior capsule opacification. METHODS A total of 40 eyes of 20 New Zealand white rabbits were randomly divided into six similar groups of 6 to 7 eyes each. After crystalline lens evacuation, one control group (group A) was implanted with a hydrophilic acrylic intraocular lens and no device, and another control group (g...
متن کاملPhotodisruption of a thin membrane near a solid boundary: an in vitro study of laser capsulotomy
A Nd:YAG laser photodisruption is a wellestablished tool for intraocular surgery, such as treatment of posterior capsule opacification that affects the visual function. During the intraocular procedure, called laser capsulotomy, the excitation pulse is focused several times just behind the posterior capsule and intraocular lens to create the central opening in the opacified capsule. We built an...
متن کاملCPSA Shanghai 2017 Poster Abstract Program
Objective: Evaluate the effectiveness and efficiency of cataract task forces for underprivileged communities, in a follow-up of 4 years, with the use of low price intraocular lens. Methods: Retrospective study, based on a database of a sample of 58 patients randomly selected, submitted to a cataract task force in a rural area of Pernambuco, Brazil. All surgeries were performed by the same surge...
متن کاملAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.
AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 58 14 شماره
صفحات -
تاریخ انتشار 2017