Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging.
نویسندگان
چکیده
A subsecond magnetic resonance imaging (MRI) technique for isotropic diffusion mapping is described which, in contrast to echo-planar imaging (EPI), is insensitive to resonance offsets, i.e., tissue susceptibility differences, magnetic field inhomogeneities, and chemical shifts. It combines a diffusion-weighted (DW) spin-echo preparation period and a high-speed stimulated echo acquisition mode (STEAM) MRI sequence and yields single-shot images within measuring times of 559 msec (80 echoes). Here, diffusion encoding involved one scan without DW, three DW scans with b = 490 sec mm(-2), and three DW scans with b = 1000 sec mm(-2) (orthogonal gradient orientations). An automated on-line evaluation resulted in isotropic DW images as well as ADC maps (trace of the diffusion tensor). Experiments at 2.0 T covered the brain of healthy subjects in 20 contiguous sections of 6 mm thickness and 2.0 x 2.0 mm(2) in-plane resolution within a total measuring time of 78 sec. High-resolution studies at 1.0 x 1.0 mm(2) (interpolated from 2.0 x 1.0 mm(2) acquisitions) were obtained within 5 min 13 sec using four averages. In comparison with EPI, DW single-shot STEAM MRI exhibits only about half the SNR, but completely avoids regional signal losses, high intensity artifacts, and geometric distortions.
منابع مشابه
High-field diffusion tensor imaging of mouse brain in vivo using single-shot STEAM MRI.
Information about the microstructural organization of cerebral white matter that is accessible by magnetic resonance diffusion tensor imaging (DTI) gains increasing importance for studies of animal brain. Particular challenges occur for in vivo conditions as well as at high magnetic fields. Here, we have employed a diffusion-weighted (DW) single-shot STEAM MRI sequence for DTI of mouse brain in...
متن کاملDiffusion-weighted single-shot line scan imaging of the human brain.
Single-shot line scan imaging (LSI) was adapted to diffusion-weighted (DW) MRI by replacing the initial 90 degrees radiofrequency pulse of the underlying high-speed stimulated echo sequence by a DW spin-echo preparation period. Implementation on a 2. 0 T whole-body MRI system yielded DW images of the human brain with b factors of 750 s mm(-2) and total imaging times of about 500 ms either for a...
متن کامل"Pitfalls in Diffusion: What Artifacts Should I Worry About?"
This presentation covers the sources of many common diffusion image artifacts. Some of these arise from the limitations of single-shot echoplanar imaging (EPI), including low spatial resolution, blurring effects of T2* decay and T2 decay occurring during image readout, and sensitivity to artifacts due to Nyquist ghosting, chemical shift, magnetic field inhomogeneity, and local susceptibility ef...
متن کاملTurbo spin-echo diffusion-weighted MR of ischemic stroke.
PURPOSE Our objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base. METHODS Forty subjects who were refe...
متن کاملSeparation of Fiber Tracts within the Human Cingulum Bundle using Single-Shot STEAM DTI
The cingulum bundle is a complex white matter fiber tract of the human brain that comprises long association fibers, commissural fibers, and various U-fibers. It is located above the corpus callosum and interconnects limbic structures. A decline of the cingulum fiber integrity has been observed in patients with mental disorders such as schizophrenia. In this work a separation of the bi-hemisphe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 44 5 شماره
صفحات -
تاریخ انتشار 2000