Comparison of McGrath Series 3 and Macintosh Laryngoscopes for Tracheal Intubation in Patients With Normal Airway by Inexperienced Anesthetists
نویسندگان
چکیده
Difficult and failed intubations account for the major causes of morbidity and mortality in current anesthetic practice. Several devices including McGrath Series 3 videolaryngoscope are available which may facilitate tracheal intubation by improving view of the larynx compared with Macintosh blade laryngoscopy. But no studies demonstrate whether McGrath Series 3 performs better than Macintosh laryngoscope in normal airway intubations by inexperienced anesthetists so far. We therefore designed this randomized controlled study to compare McGrath with Macintosh in routine tracheal intubation performed by inexperienced anesthetists.In total, 180 adult patients with normal-appearing airways requiring orotracheal intubation for elective surgery were randomly allocated to be intubated by 9 inexperienced anesthetists with McGrath or Macintosh. The primary outcome was time to intubation. Ease of intubation was assessed by a 5-point ordinal scale. Intubation attempts/failures, best laryngoscopy view using the Cormack-Lehane grade, associated complications and hemodynamic changes during intubation were recorded.We found that there was no significant difference between McGrath and Macintosh in the median time to intubation (P = 0.46); the Cormack-Lehane views attained using McGrath were superior (P < 0.001); the difference of ease of intubation was statistically significant (P = 0.01). No serious trauma occurred in both groups. And there was statistically significant difference in the systolic blood pressure changes between 2 groups (P < 0.05).We demonstrated that in orotracheal intubation in patients with normal airway by inexperienced anesthetists, McGrath compared with the Macintosh allows superior glottis views, greater ease of intubation, less complications, and hemodynamic changes with noninferior intubation time. And it remained a potential selection for inexperienced anesthetists in uncomplicated intubation.
منابع مشابه
The usefulness of the McGrath MAC laryngoscope in comparison with Airwayscope and Macintosh laryngoscope during routine nasotracheal intubation: a randomaized controlled trial
BACKGROUND McGrath MAC video laryngoscope offers excellent laryngosopic views and increases the success rate of orotracheal intubation in some cases. The aim of this study was to determine the usefulness of McGrath MAC for routine nasotracheal intubation by comparing McGrath MAC with Airway scope and Macintosh laryngoscope. METHODS A total of 60 adult patients with ASA physical status class 1...
متن کاملA prospective randomized high fidelity simulation center based side-by-side comparison analyzing the success and ease of conventional versus new generation video laryngoscope technology by inexperienced laryngoscopists
Introduction. Indirect video laryngoscopes are altering the landscape of airway management. The primary aim of this prospective randomized patient simulator analysis was to objectively compare video laryngoscopes to standard airway management techniques in novice users. Methods. "First year medical students were exposed to high-fidelity simulated normal and difficult airway scenarios while usin...
متن کاملEvaluation of the success rate and quality of teaching of tracheal intubation to medical students by using video laryngoscope
Background: Training of airway management and tracheal intubation skill in emergencies for resuscitation of patients are basic skills for medical students. However, the success rate of beginners in this skill is low. Video laryngoscopes are new devices that can increase the success of endotracheal intubation training. Methods: This clinical trial was conducted with 30 medical students who came...
متن کاملRandomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study.
BACKGROUND Several videolaryngoscopes are available which may facilitate tracheal intubation in difficult airways. We compared the McGrath(®) Series 5 and the Venner™ A.P. Advance™ (APA) videolaryngoscopes with a Macintosh laryngoscope by studying the performance of experienced anaesthetists using manikins in normal and difficult airway scenarios. METHODS We recruited 48 anaesthetists into a ...
متن کاملComparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics
BACKGROUND Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating room. The aim of this study was to compare glottic view, time of intubation and success rate of t...
متن کامل