Aortic reservoir pressure corresponds to cyclic changes in aortic volume: physiological validation in humans.

نویسندگان

  • Martin G Schultz
  • Justin E Davies
  • Ashutosh Hardikar
  • Simon Pitt
  • Michela Moraldo
  • Niti Dhutia
  • Alun D Hughes
  • James E Sharman
چکیده

OBJECTIVE Aortic reservoir pressure indices independently predict cardiovascular events and mortality. Despite this, there has never been a study in humans to determine whether the theoretical principles of the mathematically derived aortic reservoir pressure (RP(derived)) and excess pressure (XP(derived)) model have a real physiological basis. This study aimed to directly measure the aortic reservoir (AR(direct); by cyclic change in aortic volume) and determine its relationship with RP(derived), XP(derived), and aortic blood pressure (BP). APPROACH AND RESULTS Ascending aortic BP and Doppler flow velocity were recorded via intra-arterial wire in 10 men (aged 62 ± 12 years) during coronary artery bypass surgery. Simultaneous ascending aortic transesophageal echocardiography was used to measure AR(direct). Published mathematical formulae were used to determine RP(derived) and XP(derived). AR(direct) was strongly and linearly related to RP(derived) during systole (r=0.988; P<0.001) and diastole (r=0.985; P<0.001). Peak cross-correlation (r=0.98) occurred at a phase lag of 0.004 s into the cardiac cycle, suggesting close temporal agreement between waveforms. The relationship between aortic BP and AR(direct) was qualitatively similar to the cyclic relationship between aortic BP and RP(derived), with peak cross-correlations occurring at identical phase lags (AR(direct) versus aortic BP, r=0.96 at 0.06 s; RP(derived) versus aortic BP, r=0.98 at 0.06 s). CONCLUSIONS RP(derived) is highly correlated with changes in proximal aortic volume, consistent with its physiological interpretation as corresponding to the instantaneous volume of blood stored in the aorta. Thus, aortic reservoir pressure should be considered in the interpretation of the central BP waveform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of changes in instantaneous aortic blood flow by the analysis of arterial blood pressure.

The purpose of this study was to introduce and validate a new algorithm to estimate instantaneous aortic blood flow (ABF) by mathematical analysis of arterial blood pressure (ABP) waveforms. The algorithm is based on an autoregressive with exogenous input (ARX) model. We applied this algorithm to diastolic ABP waveforms to estimate the autoregressive model coefficients by requiring the estimate...

متن کامل

Lovastatin Incubation Improves Acetylcholine-Induced Relaxation in Isolated Aortic Rings of Diabetic Rat

To evaluate the acute effect of lovastatin on diabetic endothelial dysfunction, we examined this effect on the aortic rings of streptozotocin-diabetic rats. The endothelial function was assessed in aortic rings isolated from diabetic rats, 12 weeks after treatment with streptozotocin (45 mg/kg, i.p.). The concentration-response curve to acetylcholine (Ach) in the aortic rings precontracted with...

متن کامل

Aortic pressure-diameter relationship assessed by intravascular ultrasound: experimental validation in dogs.

Intravascular ultrasound (IVUS) has emerged as an important diagnostic method for evaluating vessel diameter and vessel wall motion. To evaluate the validity of IVUS in assessing changes in the pressure-diameter relationship we compared measurements of abdominal aortic diameters derived from IVUS with those simultaneously obtained at the same site using implanted sonomicrometers in five chronic...

متن کامل

Renal insufficiency after infrarenal abdominal aortic aneurysm reconstruction: An analysis of this risk factor in 45 patients

 Abstract Background: Renal insufficiency is a potential complication after infrarenal abdominal aortic aneurysm repair and is a significant risk factor for postoperative mortality and morbidity. The aim of this study was to analyze the effect of this risk factor, before and during operation. Methods: In this prospective study, between 2003 and 2006, 45 patients underwent repair of an infrarena...

متن کامل

Associations and clinical relevance of aortic-brachial artery stiffness mismatch, aortic reservoir function, and central pressure augmentation.

Central augmentation pressure (AP) and index (AIx) predict cardiovascular events and mortality, but underlying physiological mechanisms remain disputed. While traditionally believed to relate to wave reflections arising from proximal arterial impedance (and stiffness) mismatching, recent evidence suggests aortic reservoir function may be a more dominant contributor to AP and AIx. Our aim was th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arteriosclerosis, thrombosis, and vascular biology

دوره 34 7  شماره 

صفحات  -

تاریخ انتشار 2014