Blunted Tungsten Tip Cleaning by Nitrogen Gas Etching at Room Temperature without Tip Heating and Cooling
نویسندگان
چکیده
For a long time, the ultra-sharp tips are used for high resolution microscope, such as scanning tunneling microscope (STM), atomic force microscope (ATM), field emission scanning electron microscope (FE-SEM). In addition, helium ion microscope (HIM), which has sub-nanometer imaging resolution, employs the tip as gas field ionization source (GFIS) in recent years. There are a lot of required vital conditions of tip fabrication and source characterization for the high performance of microscopes. Among them, tip cleanliness and operation temperature are very essential for the stable and high charged particle beam current. The contaminants on the surface of tip will undoubtedly cause instabilities in the tunnel junction between tip and gases and abruptly increases fluctuation of the charged particle beam current, thus affecting the image quality and noise level. Also, its requirements for liquid nitrogen cooling make the microscope system complicated, expensive maintenance cost and price of apparatus. This study presents a simple and efficient way to clean the blunted tungsten tip using a field-assisted nitrogen etching at room temperature without tip heating and cooling methods.
منابع مشابه
Evaluation of Temperature Rise and Thermal Lesion Dimensions in Liver Laser Interstitial Thermotherapy
Introduction: Laser interstitial thermotherapy (LITT) is an internal ablation therapy method consisting of a percutaneous or intraoperative insertion of laser fibers directly into the liver tumor with maximum diameter of 5 cm. In this treatment method, there isn’t any general information about the relationship between increasing the exposure power, coagulation and carboniza...
متن کاملA simplified method for manufacturing glass-insulated metal microelectrodes.
A simplified method to manufacture durable, glass-insulated, tungsten microelectrodes with sufficient control of the final electrode impedance is described. This method requires only two instruments, an electrolytic etcher for wires and pipette puller, for manufacturing these electrodes. The manufacture of these electrodes involves 3 steps: (1) etching tungsten wire to sharpen the tip, (2) insu...
متن کاملOptimization of Electrochemical Etching Parameters in FIM/STM Tungsten Nanotip Fabrication
Field Ion Microscopy (FIM) and Scanning Tunneling Microscopy (STM) have found a wide application in nanotechnology. These microscopes use a metallic nanotip for image acquisition. Resolution of FIM and STM images depends largely on the radius of nanotip apex; the smaller the radius the higher the resolution. In this research, for tungsten nanotip fabrication, electrochemical etching of tungsten...
متن کاملDynamic electrochemical-etching technique for tungsten tips suitable for multi-tip scanning tunneling microscopes
We present a method to prepare tungsten tips for use in multi-tip scanning tunneling microscopes. The motivation behind the development comes from a requirement to make very long and conical-shape tips with controlling the cone angle. The method is based on a combination of a “drop-off” method and dynamic electrochemical etching, in which the tip is continuously and slowly drawn up from the ele...
متن کاملMRI active guidewire with an embedded temperature probe and providing a distinct tip signal to enhance clinical safety
BACKGROUND The field of interventional cardiovascular MRI is hampered by the unavailability of active guidewires that are both safe and conspicuous. Heating of conductive guidewires is difficult to predict in vivo and disruptive to measure using external probes. We describe a clinical-grade 0.035" (0.89 mm) guidewire for MRI right and left heart catheterization at 1.5 T that has an internal pro...
متن کامل