Evaluation of MVCT images with skin collimation for electron beam treatment planning
نویسندگان
چکیده
This study assessed the potential of using megavoltage CT (MVCT) images taken with high density skin collimation in place for electron beam treatment planning. MVCT images were taken using the TomoTherapy Hi-Art system (TomoTherapy Inc., Madison, WI), and the CT numbers were converted to density by calibrating the Hi-Art system using an electron density phantom. Doses were computed using MVCT images and kVCT images and compared by calculating dose differences in the uniform dose region ( > 90%, excluding buildup region) and calculating distance-to-agreement (DTA) in high dose-gradient regions (penumbra and distal falloff, 90%-10%). For 9 and 16 MeV electron beams of 10 x 10 cm calculated on a homogeneous CIRS Plastic Water (Computerized Imaging Research Systems Inc., Norfolk, VA) phantom without skin collimation, the maximum dose differences were 2.3% and the maximum DTAs were 2.0 mm for both beams. The same phantom was then MVCT scanned nine times with square skin collimators of Cerrobend on its surface - field sizes of 3 x 3, 6 x 6, and 10 x 10 cm and thicknesses of 6, 8, and 10 mm. Using the Philips Pinnacle 3 treatment planning system (Philips Medical Systems, N.A., Bothwell, WA), a treatment plan was created for combinations of electron energies of 6, 9, 12, and 16 MeV and each field size. The same treatment plans were calculated using kVCT images of the phantom with regions-of-interest (ROI) manually drawn to duplicate the sizes, shapes, and density of the skin collimators. With few exceptions, the maximum dose differences exceeded +/-5% and the DTAs exceeded 2 mm. We determined that the dose differences were due to small distortions in the MVCT images created by the high density material and manifested as errors in the phantom CT numbers and in the shape of the skin collimator edges. These results suggest that MVCT images without skin collimation have potential for use in patient electron beam treatment planning. However, the small distortion in images with skin collimation makes them unsuitable for clinical use.
منابع مشابه
Evaluation of Mvct Images with Skin Collimation for Electron Treatment Planning
.......................................................................................................................................................... x 1. Chapter
متن کاملOptimization of tomotherapy treatment planning for patients with bilateral hip prostheses
BACKGROUND To determine the effect of different imaging options and the most efficient imaging strategy for treatment planning of patients with hip prostheses. METHODS The planning kilovoltage CT (kVCT) and daily megavoltage CT (MVCT) studies for three prostate cancer patients with bilateral hip prostheses were used for creating hybrid kVCT/MVCT image sets. Treatment plans were created for kV...
متن کاملEvaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy
Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملA feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...