Histologic evaluation of the bone-ceramic interface of an alumina ceramic cup arthroplasty retrieved after 25 years in vivo

نویسندگان

  • Fuminori Higuchi
  • Shigeo Fukunishi
  • Shoji Nishio
  • Tomokazu Fukui
  • Yuki Fujihara
  • Shohei Okahisa
  • Yu Takeda
  • Shinichi Yoshiya
چکیده

A 47-year-old man underwent ceramic cup arthroplasty when he was 22 years old. Revision total hip arthroplasty was performed 25 years later because of limited range of motion without implant loosening. Histologic examination revealed that the femoral head and ceramic implant were well fixed through a thin fibrous membrane. The energy-dispersive X-ray analysis indicated that calcium and phosphorus were detected in the same peak pattern as cancellous bone in the bone-ceramic interface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.

BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...

متن کامل

Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing.

BACKGROUND The mechanical properties of alumina ceramic, now in its third generation, have been markedly improved through the evolution of design features and manufacturing processes and the introduction of proof-testing. Nonetheless, because of the lack of ductility of alumina ceramic, there is concern regarding the risk of fracture during insertion or in vivo use. The purpose of the present s...

متن کامل

Microseparation and stripe wear in alumina-on-alumina hip implants.

The combination of materials that still has highest wear resistance for total hip replacement is ceramic-on-ceramic. However, brittleness is a major concern for ceramics: in vivo and in vitro studies on ceramic hip prostheses correlate microseparation with hip noise, ceramic wear, or ceramic liner damage. Ceramic microseparation can lead to edge load, ceramic head wear, and squeaking. The aim o...

متن کامل

Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.

BACKGROUND While most reports of component fracture following alumina-on-alumina total hip arthroplasty have involved the acetabular liner, few have involved fracture of the alumina femoral head. In the present multicenter study, we investigated ceramic head fractures in a cohort of patients who underwent third-generation alumina-on-alumina total hip arthroplasty. METHODS We performed a retro...

متن کامل

Ceramic-ceramic and metal-polyethylene total hip replacements: comparison of pseudomembranes after loosening.

We made a semiquantitative study of the comparative histology of pseudomembranes from 12 loose cemented ceramic-ceramic and 18 metal-polyethylene total hip replacements. We found no significant difference in cellular reaction between the two groups, but there was a major difference in the origin of the particulate debris. In the metal-polyethylene group, polyethylene of articular origin was pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016