Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum.
نویسندگان
چکیده
Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Samples of first-milking MC were collected from 7 dairy farms in Maine, New Hampshire, Vermont, and Connecticut (n=84) and 1 dairy farm in California (n=99). The MC was milked from the cow at 6.1 ± 5.6h postparturition and a sample was evaluated for Brix percentage by using an optical refractometer. Two additional samples (30 mL) were collected from the milk bucket, placed in vials, and frozen before analysis of total IgG by radial immunodiffusion (RID) using commercially available plates and by turbidimetric immunoassay (TIA). The second sample was analyzed for total bacterial counts and coliform counts at laboratories in New York (Northeast samples) and California (California samples). The Brix percentage (mean ± SD) was 23.8 ± 3.5, IgG concentration measured by RID was 73.4 ± 26.2g/L, and IgG concentration measured by TIA was 67.5 ± 25.0 g/L. The Brix percentage was highly correlated (r=0.75) with IgG analyzed by RID. The Brix percentage cut point to define high- or low-quality colostrum (50 g of IgG/L measured by RID) that classified more samples correctly given the proportion of high- (86%) and low-quality (14%) samples in this study was 21%, which is slightly lower than other recent estimates of Brix measurements. At this cut point, the test sensitivity, specificity, positive and negative predictive values, and accuracy were 92.9, 65.5, 93.5, 63.3, and 88.5%, respectively. Measurement of IgG by TIA correlated with Brix (r=0.63) and RID (r=0.87); however, TIA and RID methods of IgG measurement were not consistent throughout the range of samples tested. We conclude that Brix measurement of total solids in fresh MC is an inexpensive, rapid, and satisfactorily accurate method of estimating IgG concentration. A cut point of 21% Brix to estimate samples of MC >50 g/L was most appropriate for our data. Measurement of IgG in MC by TIA differed from measurement by RID.
منابع مشابه
Evaluation of an on-farm method to assess colostrum IgG content in sows.
The objective of this work was to investigate the evaluation of swine colostrum immunoglobulin G (IgG) concentration using the Brix refractometer. Colostrum samples were collected across all teats, from 124 sows of mixed parities. According to sampling time, three categories were created: samples available from 9 h before the onset of parturition until the first piglet was born were classified ...
متن کاملCovariance structures of fat and protein influence the estimation of IgG in bovine colostrum.
On-farm instruments for assessing colostrum quality are needed in order to ensure that the calf is supplied with enough IgG to avoid failure of passive transfer. The aim of this study was to evaluate methods for estimating the IgG concentration in cows' colostrum. This research included 126 colostrum samples from 21 Danish farms with different breeds, ensuring a broad variation pattern in IgG, ...
متن کاملTechnical note: Use of a digital and an optical Brix refractometer to estimate total solids in milk replacer solutions for calves.
The Brix refractometer is used on dairy farms and calf ranches for colostrum quality (estimation of IgG concentration), estimation of serum IgG concentration in neonatal calves, and nonsalable milk evaluation of total solids for calf nutrition. Another potential use is to estimate the total solids concentrations of milk replacer mixes as an aid in monitoring feeding consistency. The purpose of ...
متن کاملEffect of Heat‐treatment on Accuracy of Infrared Spectroscopy and Digital and Optical Brix Refractometers for Measuring Immunoglobulin G Concentration in Bovine Colostrum
BACKGROUND Heat-treatment of colostrum is a method developed to reduce calf exposure to pathogens. Infrared (IR) spectroscopy and Brix refractometers can be used for measuring colostral IgG concentration and assessing colostrum quality. OBJECTIVES To determine the impact of heat-treatment on accuracy of IR spectroscopy and Brix refractometers for measuring colostral IgG concentration and asse...
متن کاملComparison of four methods to assess colostral IgG concentration in dairy cows.
OBJECTIVE To determine sensitivity and specificity of 4 methods to assess colostral IgG concentration in dairy cows and determine the optimal cutpoint for each method. DESIGN Cross-sectional study. ANIMALS 160 Holstein dairy cows. PROCEDURES 171 composite colostrum samples collected within 2 hours after parturition were used in the study. Test methods used to estimate colostral IgG concen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dairy science
دوره 96 2 شماره
صفحات -
تاریخ انتشار 2013