Low-molecular-weight heparin as a bridging anticoagulant early after mechanical heart valve replacement.

نویسندگان

  • Philippe Meurin
  • Jean Yves Tabet
  • Hélène Weber
  • Nathalie Renaud
  • Ahmed Ben Driss
چکیده

BACKGROUND After mechanical heart valve replacement (MHVR), long-term use of unfractionated heparin is sometimes required because vitamin K antagonists (VKA) are temporarily contraindicated or because the time to reach the target international normalized ratio is long. The aim of this study was to investigate the feasibility of low-molecular-weight heparin treatment in these patients. METHODS AND RESULTS This work was conducted as a prospective study. We selected all patients (n=695) who underwent MHVR and were transferred to a postoperative cardiac rehabilitation center between January 2000 and January 2005. The study focused on patients who had not yet started VKA therapy or who had a below-target international normalized ratio despite VKA therapy. Unfractionated heparin was replaced by enoxaparin (100 IU/kg BID) until VKA treatment was fully effective. Two hundred fifty patients (60+/-11 years old) were enrolled 16+/-11 days after surgery (aortic valve replacement, n=190; mitral valve replacement, n=34; double valve replacement, n=26). Of these, 50% had permanent or transient atrial fibrillation, 40% had hypertension, 13% had diabetes, and 19% had a history of cardiac surgery. The mean duration of low-molecular-weight heparin treatment was 8.3+/-6.0 days. Patients were followed for 90 days, during which there were two major and three minor bleeding episodes and one transient ischemic attack. There were no cases of valve thrombosis and no deaths. CONCLUSIONS After MHVR, one third of patients leave the cardiac surgery unit before VKA treatment is fully effective. Bridging anticoagulation therapy with enoxaparin appears to be feasible during this high-risk period for thromboembolism and could shorten the length of hospital stay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early Postoperative Anticoagulation by Enoxaparin after Mechanical Aortic Valve Replacement

Background: The use of low molecular weight heparin for early anticoagulation after mechanical aortic valve replacement is still a matter of debate even more that the early postoperative phase is associated with maximum of thrombo-embolic and bleeding risks. The objective of this study is to verify the efficacy and the safety of low molecular weight heparin for the early anticoagulation after m...

متن کامل

Exclusive low-molecular-weight heparin as bridging anticoagulant after mechanical valve replacement.

BACKGROUND Unfractionated heparin has been the standard anticoagulant used immediately after mechanical heart valve replacement (MHVR). The purpose of this study was to assess a postoperative anticoagulation protocol with low-molecular-weight heparin (LMWH) immediately after MHVR without the use of unfractionated heparin or anti-factor Xa monitoring. METHODS We performed a prospective, single...

متن کامل

"Bridging" and mechanical heart valves: perils, promises, and predictions.

Measurement of the prothrombin time, which is standardized by reporting the result as the international normalized ratio (INR), assesses the anticoagulant effect of warfarin. For most mechanical heart valves, the target INR ranges between 2.0 and 3.5. In the postoperative cardiac surgical setting, patients are usually started on low doses of warfarin because they tend to have impaired hepatic m...

متن کامل

Low molecular weight heparin after mechanical heart valve replacement.

BACKGROUND Patients with mechanical heart valves require life-long anticoagulation. We report here the first large and comparative series of consecutive patients anticoagulated with low molecular weight heparin (LMWH) after mechanical heart valve replacement. METHODS AND RESULTS In this comparative, nonrandomized study, 208 consecutive patients who underwent a single or double heart valve rep...

متن کامل

Maternal and Fetal Outcomes in Pregnant Women with a Prosthetic Mechanical Heart Valve

BACKGROUND Pregnancy is associated with several cardiocirculatory changes that can significantly impact underlying cardiac disease. These changes include an increase in cardiac output, sodium, and water retention leading to blood volume expansion, and reductions in systemic vascular resistance and systemic blood pressure. In addition, pregnancy results in a hypercoagulable state that increases ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 2006