Effect of Blood Volume in Standard Anaerobic Blood Culture Bottles of the BacT/ALERT 3D System Used for the Detection of Pathogens and Time to Detection
نویسندگان
چکیده
BACKGROUND Blood volume may profoundly affect the isolation of microorganisms in blood cultures. The effect of blood volume in standard anaerobic bottles of the BacT/ALERT 3D system was investigated. METHODS Adult patients who visited the emergency department and referred for blood culture (n = 824) were enrolled from June to September 2013. Two sets of blood cultures were obtained from each patient. One set consisted of 5 mL that was collected in a standard aerobic bottle (SA5), 5 mL that was collected in a standard anaerobic bottle (SN5), and 10 mL that was collected in a standard anaerobic bottle (SN10). The growth of clinically significant pathogens and the time to detection (TTD) were compared between the SN5 and SN10 samples. RESULTS Increasing the volume of blood collected from 5 to 10 mL yielded a 14.7% improvement in the isolation of microorganisms. There was a statistically significant difference in the isolation of pathogens (14 vs. 30, P = 0.023) between the SN5 and SN10 samples. Gram-positive microorganisms were detected earlier in the SN10 samples than the SN5 samples (P = 0.052). The mean TTD of all pathogens was 13.5 h for the SN5 samples and 12.9 h for the SN10 samples (P = 0.099). CONCLUSION Increased blood volume in the SN bottle yielded a significantly higher pathogen detection rate. However, there was no difference in the frequency of earlier detection or TTD between the SN5 and SN10 samples.
منابع مشابه
Growth Dynamics of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa as a Function of Time to Detection in BacT/Alert 3D Blood Culture Bottles with Various Preincubation Conditions
BACKGROUND Delayed entry of blood culture bottles is inevitable when microbiological laboratories do not operate for 24 hr. There are few studies reported for prestorage of these bottles. The growth dynamics of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were investigated with respect to various preincubation conditions. METHODS Fifteen or 150 colony-forming units (CFU...
متن کاملControlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.
A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instrum...
متن کاملControlled clinical comparison of VersaTREK and BacT/ALERT blood culture systems.
To assess the relative yields in automated microbial detection systems of bacteria and yeasts isolated from the blood of adult patients with suspected sepsis, we compared the new VersaTREK system (VTI) (TREK Diagnostic Systems, Cleveland, OH) to the BacT/ALERT 3D system (3D) (bioMérieux, Inc., Durham, NC). Identical protocols were followed for the two systems. Paired aerobic (REDOX 1) and anaer...
متن کاملControlled clinical comparison of the BacT/ALERT FN and the standard anaerobic SN blood culture medium.
To determine the optimal anaerobic companion bottle to pair with the BacT/ALERT (bioMerieux, Durham, N.C.) nonvented aerobic FA (FA) medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared the BacT/ALERT FN (FN) anaerobic bottle with the standard BacT/ALERT SN (SN) anaerobic bottle. Each bottle, FA, FN, and SN, was filled with 8 to 12 ml of...
متن کاملThe Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS
Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had highe...
متن کامل