Calibration of fundus images using spectral domain optical coherence tomography.

نویسندگان

  • Brandon J Lujan
  • Fenghua Wang
  • Giovanni Gregori
  • Philip J Rosenfeld
  • Robert W Knighton
  • Carmen A Puliafito
  • Ronald P Danis
  • Larry D Hubbard
  • Robert T Chang
  • Donald L Budenz
  • Michael I Seider
  • O'Rese Knight
چکیده

BACKGROUND AND OBJECTIVE Measurements performed on fundus images using current software are not accurate. Accurate measurements can be obtained only by calibrating a fundus camera using measurements between fixed retinal landmarks, such as the dimensions of the optic nerve, or by relying on a calibrated model eye provided by a reading center. However, calibrated spectral domain OCT (SD-OCT) could offer a convenient alternative method for the calibration of any fundus image. PATIENTS AND METHODS The ability to measure exact distances on SD-OCT fundus images was tested by measuring the distance between the center of the fovea and the optic nerve. Calibrated SD-OCT scans measuring 6 X 6 X 2 mm centered on the fovea and the optic nerve were analyzed in 50 healthy right eyes. The foveal center was identified using cross-sectional SD-OCT images, and the center of the optic nerve was identified manually. The SD-OCT scans were registered to each other, and the distances between the center of the optic nerve and fovea were calculated. The overlay of these SD-OCT fundus images on photographic fundus images was performed. RESULTS Any image of the fundus could be calibrated by overlaying the SD-OCT fundus image, and the measurements were consistent with previously defined calibration methods. The mean distance between the center of the fovea and the center of the optic nerve was 4.32 +/-0.32 mm. The line from the center of the optic nerve to the foveal center had a mean declination of 7.67 +/- 3.88 degrees. Mean horizontal displacement and vertical displacement were 4.27 +/- 0.29 mm and 0.58 +/- 0.29 mm, respectively. CONCLUSIONS The overlay of the SD-OCT fundus image provides a convenient method for calibrating any image of the fundus. This approach should provide a uniform standard when comparing images from different devices and from different reading centers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Bone Remodeling in Choroidal Osteoma Monitored by Fundus Photography and Spectral-Domain Optical Coherence Tomography.

Choroidal osteoma is a benign ossifying tumor of the choroid, consisting of mature bone tissue. It has been described to enlarge and evolve at varying rates over time. Here, we report and quantify the progression of a unilateral choroidal osteoma in a 7-year-old boy by fundus photography, and document tumor remodeling by spectral domain optical coherence tomography images.

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Spectral domain optical coherence tomography guided photodynamic therapy for choroidal hemangioma: a case report

INTRODUCTION Circumscribed choroidal hemangiomas are vascular tumors associated with secondary changes in the overlying retinal pigment epithelium and neuro-sensory retina. Spectral-domain optical coherence tomography, a recent advancement in fundus imaging techniques provides high resolution images of the retina. We describe spectral domain Optical coherence tomography findings in a case of ci...

متن کامل

Imaging serpiginous choroidopathy with spectral domain optical coherence tomography.

The use of spectral domain optical coherence tomography (SD-OCT) in the study of chronic serpiginous choroiditis was evaluated. Two patients with chronic serpiginous choroiditis were imaged using two prototype SD-OCT systems (6-microm axial resolution). Raster scans covering 6 x 6 X 2-mm regions of the retina were obtained, enabling the study of different retinal cross-sectional images. Thickne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye

دوره 39 4 Suppl  شماره 

صفحات  -

تاریخ انتشار 2008