Ultra Low Pressure-drop Helium-cooled Porous-tungsten Pfc
نویسندگان
چکیده
A new class of helium-cooled high heat-flux plasma facing heat exchanger (HX) concept is presented. These unique “Foam-In-Tube” HX concepts are composed of a thin tungsten shell integrally bonded to an open-cell tungsten foam core. High heat flux tests show maximum heat loads of 22.4 MW/m using 4 MPa helium at a flow rate of 27 g/s. Based on these impressive performance results, a unique and scalable heat exchanger channel with ultra-low pressure drop through the porous foam is presented. The primary advantage of the new concept is that pressure drop through the porous media and structure temperatures are nearly independent of HX tube length. The concept is modular in design and can be combined to meet divertor size requirements. From a manufacturing and reliability point of view, the advantage of the proposed concept is that it minimizes the need for joining to other functional materials.
منابع مشابه
Structured Porous Media for High Heat Flux Fusion Applications
Effective heat transfer is essential for fusion power core components in order to enable the maximum possible power density and power conversion efficiency needed for economic competitiveness and fuel conservation. Helium coolant is particularly attractive for fusion power plant applications due to its inherent safety features. It can be used in conjunction with a refractory metal such as tungs...
متن کاملOptimization of Pin-fin Arrays for Helium-cooled Finger-type Divertor
The helium-cooled modular divertor concept with integrated pin array developed by the Karlsruhe Research Center (FZK) is unusual among helium-cooled tungsten divertor designs in that it relies upon an array of pin fins on the back of the cooled surface, instead of jet impingement, to cool the plasma-facing surface. The Georgia Tech group experimentally studied a similar design constructed of br...
متن کاملar X iv : c on d - m at / 0 60 56 80 v 1 [ co nd - m at . o th er ] 2 7 M ay 2 00 6 Supersolid helium at high pressure
Recently we reported the observation of superfluidity in solid He confined inside porous Vycor glass with characteristic pore diameter of 7 nm [1], porous gold with pore diameter of 490 nm [2] and also in bulk solid He [3]. In the bulk experiment solid helium is confined in an annular channel inside the torsion bob (see inset III of Fig.1). The width, depth and outer diameter of the channel are...
متن کاملStatus of development of the EU He-cooled divertor for DEMO
A modular He-cooled divertor concept for DEMO is being investigated at Forschungszentrum Karlsruhe (FZK) within the framework of the EU power plant conceptual study. The design goal is to reach a heat flux of at least 10 MW/m. The reference design HEMJ (helium-cooled modular divertor with jet cooling) consists of a hexagonal tungsten tile which is brazed to a thimble made of W-1%La2O3. The cool...