Variation in electrosurgical vessel seal quality along the length of a porcine carotid artery.

نویسندگان

  • Hayley Louise Wyatt
  • Rosie Richards
  • Rhys Pullin
  • Th Jimmy Yang
  • Emma J Blain
  • Sam L Evans
چکیده

Electrosurgical vessel sealing has been demonstrated to have benefits for both patients and practitioners, but significant variation in the strength of the seal continues to be a concern. This study aims to examine the variation in electrosurgical seal quality along the length of a porcine common carotid artery and explore the relationships between seal quality, vessel size and morphology. Additionally, the study aimed to investigate the minimum safety threshold for successful seals and the influence of vessel characteristics on meeting this requirement. A total of 35 porcine carotid arteries were sealed using the PlasmaKinetic Open Seal device (Gyrus). Each seal was burst pressure tested and a sample taken for staining with elastin van Gieson's stain, with morphological quantification using image processing software ImageJ. With increasing distance from the bifurcation, there was an increase in seal strength and a reduction in both elastin content and vessel outer diameter. A significant correlation was found between burst pressure with both outer diameter (p < 0.0001) and elastin content (p = 0.001). When considering the safe limits of operation, vessels of less than 5 mm in outer diameter were shown to consistently produce a seal of a sufficient strength (burst pressure > 360 mmHg) irrespective of vessel morphology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deformation During the Electrosurgical Vessel Sealing Process

Electrosurgical vessel sealing is used throughout many surgical procedures with the benefits of the device widely reported. However, there is still significant variation in the quality of the resulting seal with limited understanding as to why. This study developed a methodology to use digital image correlation to capture the sealing process and to investigate the changes occurring throughout. ...

متن کامل

Rare Variation in the Right Vertebral Artery

The variations of vertebral artery are important with regard to their potential clinical impact .The study reports the variation of course of right vertebral artery in male cadaver. The vertebral arteries arise from the superioposterior aspect of the first part of subclavian artery. The vessel takes a vertical course to enter into the transverse foramen of sixth cervical vertebra. Right vertebr...

متن کامل

Report of a Variation of the Right Common Carotid Artery

Carotid artery is the most important artery that carries the major part of the blood supply to the head and neck. The branching of the common carotid artery usually occurs at the upper edge of the thyroid cartilage. The placement of carotid sinus has also increased its importance in this area. Considering the clinical importance of knowledge about carotid artery variations, this case is reporte...

متن کامل

Evaluation of Diameter Changes, Stress-strain Elastic Modulus and Stiffness in Normal and Atherosclerotic Common Carotid Arteries in Both Sex Based on End Pressure Variation

Evaluation of elastic properties of major arteries is subject of great interest with respect to the development of vascular diseases. In this study changes in diameter and cross-sectional area, stress-strain elastic modulus and stiffness of the common carotid arteries in healthy and atherosclerotic women and men were evaluated by using indirect end pressure changes. Variations in diameter and c...

متن کامل

INFLUENCE OF ENDO THELIUM REMOVAL AND LNAME ON RESPONSES OF RAT COMMON CAROTID ARTERY TO α-ADRENOCEPTOR AGONISTS

In this study we investigated the effects of endothelium removal and L-NAME on responses to α-adrenoceptor agonists. Male Wistar rats were killed by overdose with pentobarbitone sodium, after which the left and right common carotid arteries were removed. Rings of arteries 3-4 mm in length were cut from each vessel and then mounted in 10 mL isolated organ bath, bathed in Krebs maintained at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 230 3  شماره 

صفحات  -

تاریخ انتشار 2016