Identification of regional mechanical anisotropy in soft tissue analogs.
نویسندگان
چکیده
In a previous work (Raghupathy and Barocas, 2010, "Generalized Anisotropic Inverse Mechanics for Soft Tissues,"J. Biomech. Eng., 132(8), pp. 081006), a generalized anisotropic inverse mechanics method applicable to soft tissues was presented and tested against simulated data. Here we demonstrate the ability of the method to identify regional differences in anisotropy from full-field displacements and boundary forces obtained from biaxial extension tests on soft tissue analogs. Tissue heterogeneity was evaluated by partitioning the domain into homogeneous subdomains. Tests on elastomer samples demonstrated the performance of the method on isotropic materials with uniform and nonuniform properties. Tests on fibroblast-remodeled collagen cruciforms indicated a strong correlation between local structural anisotropy (measured by polarized light microscopy) and the evaluated local mechanical anisotropy. The results demonstrate the potential to quantify regional anisotropic material behavior on an intact tissue sample.
منابع مشابه
Evaluation of Soft Tissue Sarcoma Tumors Electrical Conductivity Anisotropy Using Diffusion Tensor Imaging for Numerical Modeling on Electroporation
Introduction: There is many ways to assessing the electrical conductivity anisotropyof a tumor. Applying the values of tissue electrical conductivity anisotropyis crucial in numerical modeling of the electric and thermal field distribution in electroporationtreatments. This study aims to calculate the tissues electrical conductivityanisotropy in patients with sarcoma tumors using diffusion tens...
متن کاملInvestigating Effective Parameters in Tactile Determination of Artery included in Soft Tissue by FEM
One of the newest ways of surgery is known as Minimally Invasive Surgery (MIS), which in spite of its benefits, because of surgeon's tactile sensing omission, causes some problems with detection of arteries and their exact positions in tissue during a surgery. In this study, tactile detection of an artery in tissue has been modeled by finite element method. In this modeling, three 2D models of ...
متن کاملTumor Detection and Morphology Assessment in the Liver Tissue Using an Automatic Tactile Robot
In this paper an automatic examination robot was developed to improve the process of cancer detection, tumor localization and geometrical shape diagnosis. A uniformly distributed compressive load was applied to the top tissue surface and the resultant mechanical stress was measured that was employed for the tumor diagnosis task. The experimental examinations were performed on the soft tissue of...
متن کاملInvestigation of Shape Functions Role on the Mesh-free Method Application in Soft Tissue Elastography
In current study, The Mesh-free method based on weak-form formulation coupled with the ultrasound imaging technique is developed. This problem consists in computing the deformation of an elastic non-homogenous phantom by numerical methods (both Mesh-free and Finite Element) and converge their results to the measured deformation by the ultrasound. The shape functions of Mesh-free are approximate...
متن کاملمحاسبه درصد خطای به وجود آمده در استفاده از فانتوم آب به جای بافت نرم برای توزیع چشمه براکیتراپی 103Pd به روش مونتکارلو
Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 133 9 شماره
صفحات -
تاریخ انتشار 2011