Paroxysmal mechanical aortic valve prosthesis dysfunction: capturing the right moment
نویسندگان
چکیده
A 62-year-old female presented to the emergency room under suspicion of acute myocardial infarction. While shopping she suddenly experienced severe chest pain and nearly collapsed. Her medical history revealed aortic valve replacement (Medtronic Hall 22 mm) 8 years before and since 5 years repeated presentations to the emergency room because of intermittent chest pain. An initial electrocardiogram (ECG) showed sinus tachycardia with transient ST elevation in leads aVR and V1 and ST depression in leads I, II, III, aVF and V3–V6 (Fig. 1), which resolved within 5 min. Physical examination, laboratory results and transthoracic echocardiography were unremarkable. Under suspicion of an acute coronary syndrome, coronary angiography was performed and showed a 70% stenosis in the second diagonal branch of the left descending artery. Because of the discrepancy between the ECG at presentation and the coronary angiography, it was decided not to perform a percutaneous coronary intervention. Immediately after the coronary angiography the patient had recurrent chest pain with remarkable ST depression. A second coronary angiography was performed which revealed non-closure of the mechanical aortic valve, causing severe aortic regurgitation (Movies 1 and 2). The patient was scheduled for valve revision. At operation dysfunction of the mechanical disk became apparent. When the disk was opened a pannus overgrowth beneath the valve was clearly visible. This was causing a block of the disk in opening position with temporarily massive aortic regurgitation (Fig. 2). After removing the mechanical prosthesis, the circular pannus overgrowth was most evident (Fig. 3). The pannus was removed and a bioprosthesis (Edwards Life Sciences Perimount Magna 23 mm) was implanted. The patient made an uncomplicated recovery. She has had no recurrent chest pain 5 months after the valve replacement. Intermittent severe aortic regurgitation due to pannus overgrowth of a mechanical prosthetic aortic valve is a serious complication and has been reported before [1–4]. The clinical presentation is varied and due to the intermittent appearance of the malfunctioning valve, the diagnosis is often difficult and can be easily overlooked. In this specific patient it was possible to diagnose this clinical problem due to the findings on angiography. However, simple cinefluoroscopy of the mechanical valve during symptoms would have diagnosed mechanical valve immobility earlier. Electronic supplementary material The online version of this article (doi:10.1007/s12471-011-0159-4) contains supplementary material, which is available to authorized users. B. J. Sorgdrager (*) : E. E. van der Wall :A. J. H. A. Scholte Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300 RC, Leiden, the Netherlands e-mail: [email protected]
منابع مشابه
Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملAortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملIntermittent, Non Cyclic Severe Mechanical Aortic Valve Regurgitation
Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. We describe an unusual case of intermittent, non cyclic mechanical aortic prosthesis dysfunction due to pannus formation with thrombus in the absence of systolic restriction of disk excursion, that presented with intermittent severe aortic regurgitation.
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملDouble Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کامل