Mathematical procedures in data recording and processing of pupillary fatigue waves
نویسندگان
چکیده
Spontaneous pupillary behaviour in darkness provides information about a subject's level of vigilance. To establish infrared video pupillography (IVP) as a reliable and objective test in the detection and quantification of daytime sleepiness, the definition of numerical parameters is an important precondition characterising spontaneous pupil behaviour adequately for further statistical procedures. The correct measurement of the pupil size, even if the lid or eyelashes are occluding the pupil, is of particular concern when testing vigilance. In this case many edge points of the pupil are detected and a fitting procedure is described that fits these edge points to a circle and excludes outliers. The first step of data preparation consists of a mathematical artefact management consisting of blink detection and elimination, followed by interpolation. Second, a fast Fourier transformation is carried out for frequencies from 0.0 to 0.8 Hz for each time segment of 82 s. Results are given in absolute and relative power of each frequency band per time segment and mean values over the entire record of 11 min. Third, the changes of the mean pupillary diameter per data window against time are shown graphically. An additional parameter referring to the pupil's tendency to instability, the pupillary unrest index (PUI), is defined by cumulative changes in pupil size based on mean values of consecutive data sequences. These mathematical procedures provide a high level of quality in both data collection and evaluation of IVP as an objective test of vigilance. In a pilot study, the pupillary behaviour of two groups were measured. One group rated themselves as alert (ten men), the other group as sleepy (12 men). The power and PUI were compared using the Mann-Whitney U-test. Both parameters show significant differences between the two groups.
منابع مشابه
Monitoring vigilance during perimetry by using pupillography.
PURPOSE. To report and present data on a method for monitoring patient vigilance during a visual field test by using pupillometry. METHODS. Pupil diameter was recorded at 60 Hz with an eye movement tracking system in 13 patients attending the glaucoma outpatient clinics at Manchester Royal Eye Hospital. The patients were instructed to fixate a central target and to press a response button when ...
متن کاملQuantitative Assessment of Muscle Fatigue for FES Research Studies
Background: Muscle fatigue is an important issue in neuromuscular rehabilitation. Better control of this phenomenon would result in better prevention of its consequent physiological damages.Objective: To provide a mathematical representation of muscle fatigue as a function of time.Methods: We conducted this study by combining the EMG-based estimation methods of muscle activation with the availa...
متن کاملMental Fatigue Assessment using recording Brain Signals: Electroencephalography
Background and Objectives: Mental fatigue is a condition triggered by prolonged cognitive activity. Mental fatigue causes brain over-activity. This is a condition where the brain cells become exhausted, hampering person productivity, and overall cognitive function. The aim of this study was to assess students’ mental fatigue using brain indices. Methods: The present descriptive - analytic stud...
متن کاملChanges in Cognitive Functions Following Violent and Football Video Games in Young Male Volunteers by Studying Brain Waves
Introduction: This research investigated the effects of violent and football video games on cognitive functions, cortisol levels, and brain waves. Methods: A total of 64 participants competed in a single-elimination tournament. Saliva samples of all players were obtained before and after the games for the assessment of cortisol levels. The cognitive performances of the players were also assess...
متن کاملمعرفی روش استفاده از سیگنال مکانومیوگرام در ارزیابی عملکرد عضلات
Background and aims Recordings of electrical activity in the muscle and surface electromyography (EMG) have been widely used in the field of applied physiology. In parallel to recording of the EMG, the detectable low-frequency vibration signal generated by the skeletal muscle has been known and well documented. As the nature of the signal has been progressively revealed, the term of mec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 38 شماره
صفحات -
تاریخ انتشار 1998