Analysis of Detection Enhancement Using Microcantilevers with Long-Slit-Based Sensors

نویسندگان

  • Abdul-Rahim A. Khaled
  • Kambiz Vafai
چکیده

The present work analyzes theoretically and verifies the advantage of utilizing rectangular microcantilevers with long-slits in microsensing applications. The deflection profile of these microcantilevers is compared with that of typical rectangular microcantilevers under the action of dynamic disturbances. Various force-loading conditions are considered. The theory of linear elasticity for thin beams is used to obtain the deflection-related quantities. The disturbance in these quantities is obtained based on wave propagation and beam vibration theories. It is found that detections of rectangular microcantilevers with long-slits based on maximum slit opening length can be more than 100 times the deflections of typical rectangular microcantilevers. Moreover, the disturbance (noise effect) in the detection quantities of the microcantilever with long-slits is found to be always smaller than that of typical microcantilevers, regardless of the wavelength, force amplitude, and the frequency of the dynamic disturbance. Eventually, the detection quantities of the microcantilever with long-slits are found to be almost unaffected by dynamic disturbances, as long as the wavelengths of these disturbances are larger than 3.5 times the microcantilever width. Finally, the present work recommends implementation of microcantilevers with long-slits as microsensors in robust applications, including real analyte environments and out of laboratory testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Deflection Enhancement Using Epsilon Assembly Microcantilevers Based Sensors

The present work analyzes theoretically and verifies the advantage of utilizing ɛ-microcantilever assemblies in microsensing applications. The deflection profile of these innovative ɛ-assembly microcantilevers is compared with that of the rectangular microcantilever and modified triangular microcantlever. Various force-loading conditions are considered. The theorem of linear elasticity for thin...

متن کامل

Effects of Fluid Environment Properties on the Nonlinear Vibrations of AFM Piezoelectric Microcantilevers

Nowadays, atomic-force microscopy plays a significant role in nanoscience and nanotechnology, and is widely used for direct measurement at atomic scale and scanning the sample surfaces. In tapping mode, the microcantilever of atomic-force microscope is excited at resonance frequency. Therefore, it is important to study its resonance. Moreover, atomic-force microscopes can be operated in fluid e...

متن کامل

Development of Diamond and Silicon MEMS Sensor Arrays with Integrated Readout for Vapor Detection

This paper reports on the development of an autonomous instrument based on an array of eight resonant microcantilevers for vapor detection. The fabricated sensors are label-free devices, allowing chemical and biological functionalization. In this work, sensors based on an array of silicon and synthetic diamond microcantilevers are sensitized with polymeric films for the detection of analytes. T...

متن کامل

Performance Enhancement of GPS/INS Integrated Navigation System Using Wavelet Based De-noising method

Accuracy of inertial navigation system (INS) is limited by inertial sensors imperfections. Before using inertial sensors signals in the data fusion algorithm, noise removal method should be performed, in which, wavelet decomposition method is used. In this method the raw data is decomposed into high and low frequency data sets. In this study, wavelet multi-level resolution analysis (WMRA) techn...

متن کامل

Analysis and Diagnosis of Partial Discharge of Power Capacitors Using Extension Neural Network Algorithm and Synchronous Detection Based Chaos Theory

Power capacitors are important equipment of the power systems that are being operated in high voltage levels at high temperatures for long periods. As time goes on, their insulation fracture rate increases, and partial discharge is the most important cause of their fracture. Therefore, fast and accurate methods have great importance to accurately diagnosis the partial discharge. Conventional me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2013