Load to failure testing of new meniscal repair devices.

نویسندگان

  • F Alan Barber
  • Morley A Herbert
  • David P Richards
چکیده

PURPOSE New all-inside meniscal repair devices include those combining sutures with anchors and that allow for an "adjustable" repair. This study's purpose was to compare the failure strength of new meniscal repair devices with suture repairs. TYPE OF STUDY Experimental laboratory biomechanical study. METHODS A single repair was placed in a vertical longitudinal peripheral tear made in fresh adult porcine menisci. Group 1 had a vertically oriented suture using the FasT-Fix (Smith & Nephew Endoscopy, Andover, MA) device. Group 2 had a horizontally oriented mattress suture using the FasT-Fix device. Group 3 had a repair using 2 Arthrex (Naples, FL) meniscal darts. The Group 4 repair used a RapidLoc (Mitek Surgical Products, Westwood, MA) device. The Group 5 repair used the Arthrotek meniscal screw (Biomet, Warsaw, IN). Group 6 had a single vertical suture, and group 7 a single horizontal suture, both of 2-0 Mersilene (Ethicon, Somerville, NJ). Load to failure testing was performed. RESULTS The vertical FasT-Fix suture had a mean load to failure of 70.9 N (1 SD +/- 33). The horizontal FasT-Fix suture had a mean load to failure of 72.1 N (+/- 23.5). The double Dart repair had a mean load to failure of 61.7 N (+/- 19). The RapidLoc repair had a mean load to failure of 43.28 N (+/- 3.98). The Arthrotek meniscal screw repair had a mean load to failure of 28.09 N (+/- 7.93). Failure occurred with device pullout of the inner rim (9 of 10) for the Darts, device pullout of the inner rim (6 of 10) and pullout of the outer rim (4 of 10) for the Arthrotek screw, and suture breakage for the FasT-Fix and the RapidLoc devices. The vertical sutures' mean load to failure was 80.43 N (+/- 8.5), and all 13 failed by suture breaking. The horizontal sutures' mean failure load was 55.9 N (+/- 18.8), and failure was by both suture breaking (6 of 10) and pulling through the meniscal tissue (4 of 10). CONCLUSIONS Some of the newer meniscal repair devices show improved loads to failure over earlier generations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tensile and shear loading stability of all-inside meniscal repairs: an in vitro biomechanical evaluation.

BACKGROUND Most biomechanical studies for evaluation of the structural properties of meniscal repairs have been performed in tensile loading scenarios perpendicular to the circumferential meniscal fibers. However, meniscal repair constructs are also exposed to shear forces parallel to the circumferential meniscal fibers during healing, particularly in the midportion of the meniscus. HYPOTHESI...

متن کامل

Shear force at failure and stiffness of all-inside meniscal repair devices.

The purpose of this study was to determine the failure load and stiffness of various meniscal repair devices. A total of 61 fresh-frozen porcine menisci (medial and lateral) were used for the study. A 30-mm vertical, full-thickness tear was created and repaired using one of three all-inside fixation devices and one inside-out repair in the vertical mattress pattern. We used the MaxBraid (Biomet...

متن کامل

A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

BACKGROUND Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compar...

متن کامل

Arthroscopic Meniscal Repair: “Modified Outside-In Technique”

Background:  Despite the introduction of different techniques for meniscal repair, no single procedure is superior in all situations. The new method for meniscal repair named “ modified outside-in technique ” aims to achieve higher primary fixation strength by an alternative suture technique as well as avoid disadvantages of outside-in, inside-out, and all-inside suture procedures. Additionally...

متن کامل

All-inside meniscus repair: a systematic review.

All-inside meniscus repairs are becoming more common with the invention of meniscal arrows, darts, screws, staples, and other suture devices. With the rising popularity of these new all-inside meniscal repair devices, it is necessary to assess the effectiveness of various all-inside surgical interventions used in the treatment of meniscal tears. We performed an evidence based review of the outc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2004