Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.
نویسندگان
چکیده
With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing.
منابع مشابه
A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints.
More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily a...
متن کاملTribology of Prosthetic Joints – Validation of Wear Simulation Methods
In hip and knee arthroplasty, loosening of prosthetic components is the principal reason for expensive and complicated reoperations. Loosening is believed to be caused mainly by tissue reactions to wear particles removed from ultrahigh molecular weight polyethylene bearing surfaces. The tissue reactions, leading to bone loss, depend on the size and amount of the particles. Wear simulators are i...
متن کاملAdvantages of Mobile-bearing Total Knee Arthroplasty
Early historical failure of total knee arthroplasty (TKA) was frequently secondary to aseptic loosening, often associated with malalignment, instability, or use of excessively constrained prosthetic components. With the addition of better surgical instrumentation and operative techniques (ligamentous balancing, improved alignment, etc.) and the use of lowerconformity prosthetic devices, looseni...
متن کاملROLLING CONTACT ORTHOPAEDIC JOINT DESIGN by
Arthroplasty, the practice of rebuilding diseased biological joints using engineering materials, is often used to treat severe arthritis of the knee and hip. Prosthetic joints have been created in a “biomimetic” manner to reconstruct the shape of the biological joint. We are at a disadvantage, however, in that metals and polymers used to replace bone and articular cartilage often wear out too s...
متن کاملWear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners
The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display-using a 3D optical scanner-wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research. Part B, Applied biomaterials
دوره 104 1 شماره
صفحات -
تاریخ انتشار 2016