Trace-level potentiometric detection in the presence of a high electrolyte background.
نویسندگان
چکیده
Polymeric membrane ion-selective electrodes (ISEs) have become attractive tools for trace-level environmental and biological measurements. However, applications of such ISEs are often limited to measurements with low levels of electrolyte background. This paper describes an asymmetric membrane rotating ISE configuration for trace-level potentiometric detection with a high-interfering background. The membrane electrode is conditioned in a solution of interfering ions (e.g., Na(+)) so that no primary ions exist in the ISE membrane, thus avoiding the ion-exchange effect induced by high levels of interfering ones in the sample. When the electrode is in contact with the primary ions, the interfering ions in the membrane surface can be partially displaced by the primary ions due to the favorable ion-ligand interaction with the ionophore in the membrane, thus causing a steady-state potential response. By using the asymmetric membrane with an ion exchanger loaded on the membrane surface, the diffusion of the primary ions from the organic boundary layer into the bulk of the membrane can be effectively blocked; on the other hand, rotation of the membrane electrode dramatically reduces the diffusion layer thickness of the aqueous phase and significantly promotes the mass transfer of the primary ions to the sample-membrane interface. The induced accumulation of the primary ions in the membrane boundary layer largely enhances the nonequilibrium potential response. By using copper as a model, the new concept offers a subnanomolar detection limit for potentiometric measurements of heavy metals with a high electrolyte background of 0.5 M NaCl.
منابع مشابه
Construction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method
In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...
متن کاملSelective Potentiometric Sensor for Isoniazid Ultra-Trace Determination Based on Fe3O4 Nanoparticles Modified Carbon Paste Electrode (Fe3O4/CPE)
Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...
متن کاملConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
متن کاملConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
متن کاملDetermination of trace amounts of Ag (I) in waste water samples by a novel potentiometric sensor based on perphenazine as an ionophore
Background and Objective: Silver is a toxic heavy metal that is used in various industries and has adverse effects on both human health and the environment. In this respect its determination with sensitive and economic analytical methods is of great importance. Materials and Methods: In this research, a novel ion selective electrode based on perphenazine as an ionophore was developed for deter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 84 24 شماره
صفحات -
تاریخ انتشار 2012