"Squirt-pull" technique for left carotid catheterization.

نویسنده

  • F J Hahn
چکیده

Using the Seldinger technique in a percutaneous femoral approach, a 7 French sidewinder femorocerebral catheter is advanced over a movable-core safety J guide wire [2] to the aortic arch , where catheterization of the left carotid is attempted initially by the conventional open-loop method with withdrawal hooking of the arterial orifice . When difficulty is encountered , the following technique can be used : The catheter tip is placed midway between the innominate artery and the left common carotid artery (fig. 1 A, position 1) or midway between the left subclavian artery and the left common carotid artery (fig . 1 B, position 1). Under fluoroscopic guidance, about 7 ml of contrast material is injected rapidly by means of a 10 ml syringe. The force of injection causes the catheter tip to be medially deflec ted (fig 1 , position 2) . The deflected catheter tip approaches the opening of the left common carotid artery, allowing the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New pull-through technique using the superficial temporal artery for transbrachial carotid artery stenting.

Carotid artery stenting (CAS) is an effective and less invasive alternative to carotid endarterectomy for internal carotid artery (ICA) stenosis, but the guiding catheter is often technically difficult to introduce into the common carotid artery (CCA) in patients with concomitant atherosclerotic disease in the peripheral vessels or aorta. A new pull-through technique between the superficial tem...

متن کامل

Report of a Variation of the Right Common Carotid Artery

Carotid artery is the most important artery that carries the major part of the blood supply to the head and neck. The branching of the common carotid artery usually occurs at the upper edge of the thyroid cartilage. The placement of carotid sinus has also increased its importance in this area. Considering the clinical importance of knowledge about carotid artery variations, this case is reporte...

متن کامل

Use of balloon pull-through technique to assist in CardioSEAL device closure of patent foramen ovale.

CardioSEAL device closure of patent foramen ovale (PFO) has been advocated for the treatment of patients with cryptogenic stroke. Using the standard delivery technique, partial deployment of the CardioSEAL device can occur, especially in patients with a thick septum secundum and/or long PFO tunnel. We hypothesized that using a left atrial-to-right atrial balloon pull-through to make the septum ...

متن کامل

Sequential hemodynamic assessment in aortic valve insufficiency in rats

OBJECTIVE: In animal models of aortic insufficiency, the right common carotid artery is typically used to damage valve leaflets; this strategy impedes subsequent assessments of left ventricular hemodynamics. The present study aimed to establish an alternative technique that would allow subsequent left ventricular catheterization to monitor sequential hemodynamics in rats with aortic insufficien...

متن کامل

ایسکمی تأخیری مغزی بدنبال ترمیم ترومای نافذ شریان کاروتید خارجی

Introduction: Penetrating trauma to anterior neck can induce cerebral ischemia due to carotid artery injury. Brain ischemia also can present after surgical carotid repairs. Early diagnosis and suitable treatment modality prevent from permanent neurologic deficit post operatively. Case Report: A 30 years old man with stab wound to zone two left side of neck underwent exploration and penrose i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 1983