The Influence of Crystal Material on Intercrystal Scattering and the Parallax Effect in PET Block Detectors: A Monte Carlo Study
نویسندگان
چکیده
It is well known that Intercrystal scattering (ICS) and the parallax effect are two major resolution limiting parameters in current PET detector designs with block detectors. More recently for the purpose of resolution recovery, investigators and manufacturers have attempted to accurately model these effects into the image reconstruction task. In this study we utilized the MCNP4C Monte Carlo code to accurately simulate and measure ICS and parallax effects in different crystal materials including BGO, LSO, LYSO, LuAP and GSO. The size of the detector module was fixed at a 52mm × 52 mm crystal array. The results showed that by increasing the incidence angle, the percentage of parallax events was considerably increased, while small increases in the ICS fraction were also observed. The point spread function of the various crystal blocks were also investigated, with BGO crystal showing slightly better FWHM values as well as position detection accuracy. The results indicate that the MCNP4C MC code is a useful tool for investigation of photons interaction in PET block detectors in order to accurately model the ICS and parallax behaviors for the purpose of resolution recovery in the new PET image reconstruction algorithms.
منابع مشابه
The Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study
Introduction: In this study, we utilized the MCNP4C Monte Carlo code to quantitatively evaluate the influence of crystal size and material on intercrystal scatter and parallax effects. Materials and Methods: For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of 511 keV photons originating from a point source and incident on the central cry...
متن کاملStudy of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملOptimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method
Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008