Intraobserver and interobserver reliability of measures of cervical sagittal rotation
نویسندگان
چکیده
BACKGROUND Diagnosis and treatment decisions of cervical instability are made, in part, based on the clinician's assessment of sagittal rotation on flexion and extension radiographs. The objective of this study is to evaluate the intraobserver and interobserver reliability of three measurement techniques in assessing cervical sagittal rotation. METHODS Fifty lateral radiographs of patients with single-level cervical degenerative disc were selected and measured on two separate occasions by three spine surgeons using three different measurement techniques. Cervical sagittal rotation was measured using three different techniques. RESULTS Intraclass correlation coefficients were most consistent for Method 2 (ICC 0.93-0.96) followed by Method 1 (ICC 0.88-0.91) and Method 3 (ICC 0.81-0.87). Intraobserver agreement (% of repeated measures within 0.5° of the original measurement) ranged between 76% and 96% for all techniques, with Method 2 showing the best agreement (92%-96%). Paired comparisons between observers varied considerably with interobserver reliability correlation coefficients ranging from 0.54 to 0.89. Method 2 showed the highest interobserver reliability coefficient (0.82, range 0.73-0.88). Method 2 was also more reliable for the classification of "instability". Intraobserver percent agreements ranged from 94 to 98% for Method 2 versus 84% to 90% for Method 1 and 78% to 86% for Method 3, while interobserver percent agreements ranged from 90% to 98% for Method 2 versus 86% to 94% for Method 1 and 74% to 84% for Method 3. CONCLUSIONS Method 2 (measuring the angle from the inferior endplate of the vertebra above the degenerative disc and the inferior endplate of the vertebra below the degenerative disc) showed the best intraobserver and interobserver reliability overall in assessing cervical sagittal rotation.
منابع مشابه
The Reliabilities of Radiographic Measurements of Cervical Sagittal Alignment in Ankylosing Spondylitis.
STUDY DESIGN This is a prospective study design. OBJECTIVE To test the interobserver and intraobserver reliabilities of 5 specific measures of global cervical sagittal alignment in patients with ankylosing spondylitis (AS), and to suggest a better means of measuring cervical sagittal alignment. SUMMARY OF BACKGROUND DATA The intraobserver and interobserver reliabilities of several different...
متن کاملThe interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture
Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...
متن کاملCervical pedicle morphometry in a Latin American population
The goal of this study was to conduct a detailed computed tomography (CT) assessment in the Brazilian population of the screw starting point, trajectory, and dimensions of pedicle in the cervical spine.Two hundred consecutive patients were retrospectively evaluated using cervical spine CT, with imaging reconstruction of each cervical vertebrae in the axial plane with 2 mm, and in sagittal recon...
متن کاملIntra and Interobserver Reliability and Agreement of Semiquantitative Vertebral Fracture Assessment on Chest Computed Tomography
OBJECTIVES To evaluate the reliability of semiquantitative Vertebral Fracture Assessment (VFA) on chest Computed Tomography (CT). METHODS Four observers performed VFA twice upon sagittal reconstructions of 50 routine clinical chest CTs. Intra- and interobserver agreement (absolute agreement or 95% Limits of Agreement) and reliability (Cohen's kappa or intraclass correlation coefficient(ICC)) ...
متن کاملReliability of classification systems for subaxial cervical injuries
STUDY DESIGN Interobserver and intraobserver reliabilityObjective: To measure and compare the interobserver and intraobserver reliability of the cervical spine injury severity score (CSISS), the subaxial injury classification (SLIC) and severity scale, and the Allen-Ferguson system in patients with subaxial cervical spine injuries presenting to the emergency department. METHODS Five examine...
متن کامل