Mid-term results of a custom-made short proximal loading femoral component.

نویسندگان

  • F S Santori
  • N Santori
چکیده

Bone preservation and physiological distribution of forces on the proximal femur are key elements in introducing a successful uncemented total hip replacement. In order to achieve this, in the mid 1990s, we developed an ultra short proximal loading custom-made component with a lateral flare, a high femoral neck osteotomy and without a diaphyseal stem. We report the outcome of 129 custom-made hydroxyapatite-coated uncemented short femoral components inserted into 109 patients between June 1995 and May 2004. The mean age of the patients was 51 years (21 to 71) and the mean follow-up was eight years (4.9 to 14.1). Bone behaviour around the implant was studied on the post-operative radiographs. The mean Harris hip score improved from 44 (8 to 66) pre-operatively to 95 (76 to 100) at final follow-up. The Western Ontario MacMaster University Osteoarthritis index was 93 of 100 at final review. None of the patients reported thigh pain. A total of five hips were revised, three for polyethylene liner exchange and two for complete revision of the acetabular component. No femoral components were revised. The radiological changes in the proximal femur were generally good, as evidenced by spot welds both on the medial and lateral aspects of the femur. No component migrated. The presence of a lateral flare and use of a high osteotomy of the femoral neck provided good clinical and radiological results. The absence of a diaphyseal portion of the stem did not impair stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System

BACKGROUND The original knee megaprostheses with fixed or rotating hinge articulation were custom made and only used for reconstruction of the knee following distal femoral or proximal tibial tumor resections. The aim of the study was to analyze the short- and mid-term results of revision total knee arthroplasty with Global Modular Replacement System (GMRS) used in difficult situations not amen...

متن کامل

Melorheostosis in proximal phalanx and metacarpal bone: a short-mid-term follow up

Melorheostosis is a rare sclerosing hyperostosis that affects the appendicular skeleton more than the axial skeleton. This disorder also affects the cutaneous and soft tissues and leads to the formation of fibrosis and contracture. Due to the unique features of melorheostosis (dripping candle wax appearance), plain radiographs are often sufficient for diagnosis. Herein we report a case of melor...

متن کامل

The Short-term Clinical Outcome of Total Hip Arthroplasty Using Short Metaphyseal Loading Femoral Stem

PURPOSE The purpose of this study was to retrospectively evaluate the short-term clinical and radiological outcomes of total hip arthroplasty (THA) with short metaphyseal loading femoral stem. MATERIALS AND METHODS We retrospectively reviewed the records of 56 cases in 47 patients who had undergone THA with short metaphyseal loading femoral stem from April 2010 to December 2011. There were 20...

متن کامل

Analysis of stress distribution around total hip stems custom-designed for the standardized Asian femur configuration

In total hip replacement (THR), bone resorption related to the foreign body reaction around the implant causes bonding failure at the bone-prosthesis interface and adversely affects the function and longevity of femoral implants. Stress shielding is thought to be one of the possible biomechanical factors that causes bone resorption, and is related to prosthesis design. We therefore investigated...

متن کامل

Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems

BACKGROUND AND PURPOSE Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 9  شماره 

صفحات  -

تاریخ انتشار 2010