A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens.
نویسندگان
چکیده
PURPOSE To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL) in high myopia. MATERIALS AND METHODS A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. RESULTS An Artisan myopia lens was implanted in 60 eyes of 36 patients with preoperative myopia ranging from -5.0 to -24.0 D. Mean patient age was 22.6 years. Mean spherical equivalent of manifest refraction stabilized by the first postoperative week. At three months follow-up, 54 eyes (90%) had a postoperative refraction within +/- 1D emmetropia and 45 eyes (75%) had uncorrected visual acuity of 20/40 or better. Seven eyes (11.6%) had loss of one Snellen line and none had loss of two Snellen lines or more at three months. The mean endothelial cell loss was 3.8% at three months, 5.2% at six months, 5.25% at 12 months and 6.38% at two years, which was not significant. Postoperative complications included anterior chamber reaction in two eyes (3.3%), rise in intraocular pressure in six eyes (10%) and dislocation of PIOL in two eyes (3.3%). CONCLUSION Implantation of Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome with few complications. Significant endothelial damage was not detected in two years of follow-up.
منابع مشابه
Outcomes of iris-fi xated toric phakic intraocular lens implantation in the correction of myopic astigmatism
METHODS: Retrospective analysis of data from patients who underwent toric iris-fi xated pIOL (Artifl ex® and Artisan®) implantation in Centro Hospitalar Lisboa Central between 2009 and 2013. Th e main parameters evaluated were best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), manifest refraction, intraocular pressure (IOP), central endothelial cell count (ECC) and complicat...
متن کاملArtisan toric phakic intraocular lens for the correction of high astigmatism.
PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...
متن کاملImplantation of an Artisan phakic intraocular lens for the correction of high myopia after penetrating keratoplasty.
We report 2 cases in which an Artisan phakic intraocular lens (IOL) (Ophtec) was used to successfully treat high myopia after penetrating keratoplasty (PKP). The first case was a 43-year-old man who had a manifest refraction of -13.75 +3.00 x 50 with a best corrected visual acuity (BCVA) of 20/40(-2) after PKP in the left eye. Approximately 9 months after implantation of the Artisan IOL, the ma...
متن کاملArtisan iris-fixated toric phakic and aphakic intraocular lens implantation for the correction of astigmatic refractive error after radial keratotomy.
We report 2 patients who had radial keratotomy (RK) to correct myopia. The first patient developed a postoperative hyperopic shift and cataract. Nine years post RK, she had intracapsular cataract extraction and implantation of an Artisan aphakic intraocular lens (IOL). Twenty years post RK, hyperopia and astigmatism progressed to +7.0 -5.75 x 100 with a best corrected visual acuity (BCVA) of 20...
متن کاملFactors affecting contrast sensitivity with the Artisan phakic intraocular lens for high myopia.
PURPOSE To evaluate the factors affecting postoperative visual function in eyes with Artisan phakic intraocular lenses (PIOLs). METHODS This study examined a retrospective noncomparative case series. Phakic IOLs were implanted in 60 eyes of 36 patients with high myopia. Contrast sensitivity for spatial frequencies of 1.1, 1.7, 2.6, 4.2, 6.6, and 10:4 cycles per degree with and without glare a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indian journal of ophthalmology
دوره 54 4 شماره
صفحات -
تاریخ انتشار 2006