Performance and Profitability Perspectives of a Co2 Based District Energy Network in Geneva’s City Center

نویسندگان

  • S. Henchoz
  • D. Favrat
چکیده

A new type of district energy network capable of providing simultaneously heating and cooling is being investigated. It is based on the use of CO2 as a heat transfer fluid by taking advantage of the latent heat of vaporization, to store and transfer heat across the network. The goal of the present study is to determine the performance of a CO2 network when applied to a real urban area. It focuses first on determining the requirements for the various thermal energy services for a part of Geneva’s city centre. The energy consumption is first computed for the energy conversion technologies now in place in this area namely fuel boilers and vapour compression chillers. Then the new energy consumption is computed if a CO2 network were used instead of the existing technology. Finally a profitability analysis of the CO2 network variant is done accounting for investment, energy purchasing, equipments replacement, operation, and maintenance costs. For an interest rate of 6% and a price of the delivered heating/cooling energy at 0.13 CHF per kWh, a net present value of 82.8 million CHF after 40 years is achieved, while the break-even is reached after 5 years of operation. INTRODUCTION District heating and cooling networks have been used to deliver energy in urban areas for many decades. Generally, these networks rely on centralized and efficient energy conversion technologies supplying heating and/or cooling to the users through a water loop. In most of the cases, the supply temperature of such a network is selected according to the most demanding consumer connected. Thus all the other users are supplied at a temperature beyond their need – often far beyond their need. Furthermore, when heating and cooling have to be supplied, two independent water loops are needed. Finally, most of the time, heat discharged by the cooling users in the district cooling network is not transferred to the district heating network, and thus not recovered. A new type of district energy network is being investigated. It is based on the use of CO2 as a heat transfer fluid. It uses the latent heat of vaporization, instead of sensible heat, to store and transfer heat. The pressure of the network is selected such that evaporation/condensation takes place at around 12 to 14 °C. This level of temperature allows free cooling to be used for most of the cooling applications, while decentralized heat pumps transfer heat, from the network to each heating user, at the required temperature level. Furthermore only two pipes are required by the network, thus allowing the recovery of waste heat from the cooling users to be recovered by the heating users. Obviously, the heat required by the heating users may, most of the time, not be strictly equal to the waste heat discharged by the cooling users. Hence, a central plant is needed such that the required amount of heat can be taken from/released into the environment. Fig 1 provides a schematic view of a CO2 network. A more detailed description of the concept is done by Weber and Favrat in [2]. A presentation of a list of possible energy services and associated conversion technologies that can be included in a CO2 network was done by Henchoz et al. in [4]. Fig. 1 Schematic representation of a CO2 based district energy network. DHC13, the 13 th International Symposium on District Heating and Cooling September 3 rd to September 4 th , 2012, Copenhagen, Denmark AREA STUDIED It was chosen to study the area of “Rues Basses” in Geneva. Data such as the energy reference area (ERA) and buildings affectation was made available to the authors by Geneva’s cantonal office for energy [12]. Fig 2 shows a map of the area studied. The area was divided in 32 groups of buildings for which the 3 possible affectations were considered:  Commercial buildings

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial analysis of the factors influencing households direct energy consumption and CO2 emission in Ardabil

Spatial analysis of the factors influencing households’ direct energy consumption and CO2 emission in Ardabil Problem Statement Carbon management and its production resources are important not only for the preservation of non-renewable resources but also for the prevention of global warming and its adverse consequences. Direct consumption of fuel and energy by households plays a major role ...

متن کامل

The multilevel analysis of the social network in the older adults on the Urban HEART-2

Background: Social network in older adults refers to the interpersonal relationships and the perception of these relationships. Given the importance of the social network, the current study was conducted to answer three pivotal questions. First, do personal and district factors affect the social network of the elderly? Second, how much share do the personal and district factors have in the soci...

متن کامل

Using system dynamics approach to identify factors affecting energy consumption and CO2 emissions in urban transport: A Case Study of Tehran

The current trend of rising energy consumption in the world has hit mankind with two major crises: first, environmental pollution, and second, the acceleration of finishing energy supplies. Energy storage and reduction of pollutants in the city plays a crucial role in the process of maintaining existing energy. Meanwhile, the transportation sector needs attention due to its importance and posit...

متن کامل

A New Optimization Algorithm for Optimal Wind Turbine Location Problem in Constantine City Electric Distribution Network Based Active Power Loss Reduction

The wind turbine has grown out to be one of the most common Renewable Energy Sources (RES) around the world in recent years. This study was intended to position the Wind Turbine (WT) on a wind farm to achieve the highest performance possible in Electric Distribution Network (EDN). In this paper a new optimization algorithm namely Salp Swarm Algorithm (SSA) is applied to solve the problem of opt...

متن کامل

Optimal energy management of the photovoltaic based distribution networks considering price responsive loads, energy storage systems and convex power flows.

Nowadays, presence of photovoltaic systems in distribution network is not without challenge and it may not have economic productivity for the system under the lack of optimal management. Energy storage systems are able to cope with this problem. Therefore, in this paper, a new method is proposed for energy management of the distribution networks in order to show that how presence of the energy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012