Placement of double-lumen endobronchial tubes. Correlation between clinical impressions and bronchoscopic findings.

نویسندگان

  • G B Smith
  • N P Hirsch
  • J Ehrenwerth
چکیده

Double-lumen endobronchial tubes were placed "blindly" in 23 patients undergoing thoracotomy. Clinical criteria suggested satisfactory positioning in all cases; however, subsequent fibreoptic bronchoscopy revealed malposition in 48%. Bronchoscopic findings included the inability to view the bronchial cuff, narrowing of the bronchial lumen of the tube at the level of the cuff and herniation of the cuff over the carina. The potential hazards associated with these findings are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical and Para-Clinical Presentations of Endobronchial Tuberculosis

Introdution: Tuberculosis (TB), with different types of respiratory tract involvements, has a high rate of mortality all around the world. Endobronchial involvement, which is a slightly common tuberculous infection, requires special attention due to its severe complications such as bronchostenosis. Aim of study of this study was describes, one type of pulmonary tuberculosis with less diagnosed ...

متن کامل

Hemodynamic and Humoral Response to Intubation with Double-lumen Endotracheal Tubes Versus Single-lumen Tubes Combined with an Endobronchial Blocker: A Randomized Clinical Trial

Introduction: Insertion of endotracheal tubes, especially large and relatively inflexible double-lumen tubes, provokes cardiovascular and humoral responses which can cause complications. Bronchial blockers, combined with conventional single-lumen tubes (SLT), serve as alternatives to double-lumen tubes (DLT) and may provoke less hemodynamic response. Methods: Forty adults scheduled for elective...

متن کامل

Measuring incisor-carina distance by fiberoptic bronchoscopy to guide the placement of a left-sided double-lumen endobronchial tube

The aim of this randomized observational study was to evaluate the effect of measuring the incisor-carina distance by fiberoptic bronchoscopy in guiding the placement of a left-sided double-lumen endobronchial tube. Fifty patients (American Society of Anesthesiologists class I-II) undergoing elective thoracic procedures requiring single-lung ventilation using a left-sided double-lumen endobronc...

متن کامل

Placement of a double lumen tube in a patient with difficult intubation due to ankylosing spondylitis--a case report.

During insertion of the double lumen tube in patients with ankylosing spondylitis, cervical neutral position should be maintained to avoid vertebral and spinal injuries. Although flexible fiberoptic bronchoscopic intubation is the gold standard, available FOB size is not compatible with that of the endobronchial lumen of the double lumen tube. This problem should be solved according to institut...

متن کامل

Comparison of the resistances of double-lumen endobronchial tubes.

The resistance of commonly-used double-lumen endobronchial tubes were measured and a detailed comparison made. Robertshaw tubes were generally found to have a lower resistance than either the Carlens or the White tubes of equivalent size, but this was not so in every case. The White tubes had a disproportionately high resistance associated with the upper lobe orifice when compared with the resi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 58 11  شماره 

صفحات  -

تاریخ انتشار 1986