Relationship between right and left ventricular function in candidates for implantable cardioverter defibrillator with low left ventricular ejection fraction

نویسندگان

  • Laura Jimenez-Juan
  • Gauri R. Karur
  • Kim A. Connelly
  • Djeven Deva
  • Raymond T. Yan
  • Rachel M. Wald
  • Sheldon Singh
  • General Leung
  • Anastasia Oikonomou
  • Paul Dorian
  • Paul Angaran
  • Andrew T. Yan
چکیده

BACKGROUND Indications for the primary prevention of sudden death using an implantable cardioverter defibrillator (ICD) are based predominantly on left ventricular ejection fraction (LVEF). However, right ventricular ejection fraction (RVEF) is also a known prognostic factor in a variety of structural heart diseases that predispose to sudden cardiac death. We sought to investigate the relationship between right and left ventricular parameters (function and volume) measured by cardiovascular magnetic resonance (CMR) among a broad spectrum of patients considered for an ICD. METHODS In this retrospective, single tertiary-care center study, consecutive patients considered for ICD implantation who were referred for LVEF assessment by CMR were included. Right and left ventricular function and volumes were measured. RESULTS In total, 102 patients (age 62±14 years; 23% women) had a mean LVEF of 28±11% and RVEF of 44±12%. The left ventricular and right ventricular end diastolic volume index was 140±42 mL/m2 and 81±27 mL/m2, respectively. Eighty-six (84%) patients had a LVEF <35%, and 63 (62%) patients had right ventricular systolic dysfunction. Although there was a significant and moderate correlation between LVEF and RVEF (r=0.40, p<0.001), 32 of 86 patients (37%) with LVEF <35% had preserved RVEF, while 9 of 16 patients (56%) with LVEF ≥35% had right ventricular systolic dysfunction (Kappa=0.041). CONCLUSIONS Among patients being considered for an ICD, there is a positive but moderate correlation between LVEF and RVEF. A considerable proportion of patients who qualify for an ICD based on low LVEF have preserved RVEF, and vice versa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Right Ventricular Ejection Fraction Is Incremental to Left Ventricular Ejection Fraction for the Prediction of Future Arrhythmic Events in Patients With Systolic Dysfunction.

BACKGROUND Left ventricular ejection fraction remains the primary risk stratification tool used in the selection of patients for implantable cardioverter defibrillator therapy. However, this solitary marker fails to identify a substantial portion of patients experiencing sudden cardiac arrest. In this study, we examined the incremental value of considering right ventricular ejection fraction fo...

متن کامل

The Relation between Left Ventricular Function and Serum Ferritin in Major Β-Thalassemia

Abstract Objective Cardiac dysfunction is a major cause of death in patients with beta thalassemia. In these patients, repeated blood transfusion, ineffective erythropoiesis and increased gastrointestinal iron absorption lead to iron overload in the body and this induced heart failure. Left ventricular ejection fraction was measured in major beta thalassemia (β-Th) patients to detect the rela...

متن کامل

Heart Failure Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy

Background—Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Auto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2017