A cryogenic differential accelerometer has been developed to test the weak equivalence principle to a few parts in 10(15) within the framework of the general relativity accuracy test in an Einstein elevator experiment. The prototype sensor was designed to identify, address, and solve the major issues associated with various aspects of the experiment. This paper illustrates the measurements conducted on this prototype sensor to attain a high quality factor (Q ∼ 10(5)) at low frequencies (<20 Hz). Such a value is necessary for reducing the Brownian noise to match the target acceleration noise of 10(-14) g/√Hz, hence providing the desired experimental accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and performance analysis of a seismic grade resonance nano accelerometer

In this paper, design and performance analysis of a resonance nanosensor for earthquake low frequency geoacoustic waves detection is proposed. The model comprises of a proof mass suspended to the substrate, and a nanobeam attached to the intersection of the proof mass to the substrate. The nanobeam could be cosidered as a clamped-clamped nanoresonator actuated electrostartically. The induced ac...

متن کامل

Design and Fabrication of a Differential Electrostatic Accelerometer for Space-Station Testing of the Equivalence Principle

The differential electrostatic space accelerometer is an equivalence principle (EP) experiment instrument proposed to operate onboard China's space station in the 2020s. It is designed to compare the spin-spin interaction between two rotating extended bodies and the Earth to a precision of 10(-12), which is five orders of magnitude better than terrestrial experiment results to date. To achieve ...

متن کامل

Calibration of an Inertial Accelerometer using Trained Neural Network by Levenberg-Marquardt Algorithm for Vehicle Navigation

The designing of advanced driver assistance systems and autonomous vehicles needs measurement of dynamical variations of vehicle, such as acceleration, velocity and yaw rate. Designed adaptive controllers to control lateral and longitudinal vehicle dynamics are based on the measured variables. Inertial MEMS-based sensors have some benefits including low price and low consumption that make them ...

متن کامل

Design Modification of Rogowski Coil for Current Measurement in Low Frequency

The principle object of this paper is to offer a modified design of Rogowski coil based on its frequency response. The improvement of the integrator circuit for nullifying the phase difference between the waveforms of the measured-current and the corresponding terminal voltage is a further object of this investigation. This paper addresses an accurate, yet more efficient measuring and protect...

متن کامل

A Low Power Low Voltage Rail to Rail Constant gm Differential Amplifier with 150 dB CMRR and Enhanced Frequency Performance

This paper proposes a low voltage (±0.55V supply voltage) low power (44.65µW) high common mode rejection ratio (CMRR) differential amplifier (d.a.) with rail to rail input common mode range (ICMR), constant transconductance (gm) and enhanced frequency performance. Its high performance is obtained using a simple negative averaging method so that it cancels out the common mode input signals at th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 85 1  شماره 

صفحات  -

تاریخ انتشار 2014