Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro

نویسندگان

  • Jia Ke
  • Shao-Xing Zhang
  • Lei Hu
  • Chang-Sheng Li
  • Yun-Feng Zhu
  • Shi-Long Sun
  • Li-Feng Wang
  • Fu-Rong Ma
چکیده

BACKGROUND A single drilled tunnel from the lateral mastoid cortex to the cochlea via the facial recess is essential for minimally invasive cochlear implant surgery. This study aimed to explore the safety profile of this kind of new image-guided and bi-planar device-assisted surgery procedure in vitro. METHODS Image-guided minimally invasive cochlear implantations were performed on eight cadaveric temporal bone specimens. The main procedures were: (1) temporal bone specimens were prepared for surgery and fiducial markers were registered. (2) computed tomography (CT) scans were performed for future reference. (3) CT scan images were processed and drill path was planned to minimize cochlear damage. (4) bi-planar device-assisted drilling was performed on the specimens using the registration. (5) surgical safety was evaluated by calculating the deviation between the drill and the planned paths, and by measuring the closest distance between the drilled path and critical anatomic structures. RESULTS Eight cases were operated successfully to the basal turn of the cochlear with intact facial nerves (FNs). The deviations from target points and entrance points were 0.86 mm (0.68-1.00 mm) and 0.44 mm (0.30-0.96 mm), respectively. The angular error between the planned and the drilled trajectory was 1.74° (1.26-2.41°). The mean distance from the edge of the drilled path to the FN and to the external canal was 0.60 mm (0.35-0.83 mm) and 1.60 mm (1.30-2.05 mm), respectively. In five specimens, the chorda tympani nerves were well preserved. In all cases, no injury happened to auditory ossicles. CONCLUSIONS This exploratory study demonstrated the safety of the newly developed image-guided minimally invasive cochlear implantation assisted by the bi-planar device and established the operational procedures. Further, more in vitro experiments are needed to improve the system operation and its safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Surgical Complications of Cochlear Implantation

Cochlear implantation is a method used for the treatment of patients with profound hearing loss. This procedure may the accompanied by some major or minor complications. We evaluated the surgical complications of cochlear implantation in Fars province (south of Iran). A total of 150 patients with cochlear implantation were enrolled in the present study. Most of the patients were pre-lingual chi...

متن کامل

Robot-assisted implantation improves the precision of component position in minimally invasive TKA.

Minimally invasive and robot-assisted procedures have potential advantages when used for total knee arthroplasty (TKA). The purpose of this cadaveric study was to examine whether robot-assisted minimally invasive procedures improve TKA alignment after modifying the robotic techniques and instruments. Total knee arthroplasties were performed on 10 pairs of fresh cadaveric femora. Ten knees were ...

متن کامل

Expressive Language Development in 45 Cochlear Implanted Children Following 2 Years of Implantation

Objectives: Profound hearing loss encounters children with delay in speech and language. As it is known language acquisition in young deaf children is a lengthy process, but cochlear implanted children have better spoken language skills than if they had not received the device. According to the importance of cochlear implant in deaf childchr('39')s language development, this study evaluates the...

متن کامل

Mechatronic Feasibility of Minimally Invasive, Atraumatic Cochleostomy

Robotic assistance in the context of lateral skull base surgery, particularly during cochlear implantation procedures, has been the subject of considerable research over the last decade. The use of robotics during these procedures has the potential to provide significant benefits to the patient by reducing invasiveness when gaining access to the cochlea, as well as reducing intracochlear trauma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 129  شماره 

صفحات  -

تاریخ انتشار 2016