Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method.
نویسندگان
چکیده
Purpose To evaluate the accuracy of IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio. Methods Nine hundred twenty-eight eyes from 928 reference subjects and 158 eyes from 158 cataract patients who underwent phacoemulsification surgery were enrolled. Adjusted corneal power of cataract patients was calculated using the fictitious refractive index that was obtained from the geometric mean posterior/anterior corneal curvature radii ratio of reference subjects and adjusted anterior and predicted posterior corneal curvature radii from conventional keratometry (K) using the posterior/anterior corneal curvature radii ratio. The median absolute error (MedAE) based on the adjusted corneal power was compared with that based on conventional K in the Haigis and SRK/T formulae. Results The geometric mean posterior/anterior corneal curvature radii ratio was 0.808, and the fictitious refractive index of the cornea for a single Scheimpflug camera was 1.3275. The mean difference between adjusted corneal power and conventional K was 0.05 diopter (D). The MedAE based on adjusted corneal power (0.31 D in the Haigis formula and 0.32 D in the SRK/T formula) was significantly smaller than that based on conventional K (0.41 D and 0.40 D, respectively; P < 0.001 and P < 0.001, respectively). The percentage of eyes with refractive prediction error within ± 0.50 D calculated using adjusted corneal power (74.7%) was significantly greater than that obtained using conventional K (62.7%) in the Haigis formula (P = 0.029). Conclusions IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio provided more accurate refractive outcomes than calculation using conventional K.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملTotal corneal power estimation: ray tracing method versus gaussian optics formula.
PURPOSE To evaluate with the use of corneal topographic data the differences between total corneal power calculated using ray tracing (TCP) and the Gaussian formula (GEP) in normal eyes, eyes that previously underwent laser in situ keratomileusis/photorefractive keratectomy (LASIK/PRK), and theoretical models. METHODS TCP and GEP using mean instantaneous curvature were calculated over the cen...
متن کامل[Trial of new intraocular lens power calculation following phototherapeutic keratectomy].
We reviewed the SRK-II method and introduce a new equation to calculate the intraocular lens (IOL) power for eyes which underwent laser phototherapeutic keratectomy (PTK). The Gullstrand series was used to determine the power and the radius of curvature of planoconvex IOLs which alter the focal point from the cornea to reach the conjugate point on the retina. The radius of anterior corneal curv...
متن کاملEstimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula.
PURPOSE To describe a new formula, BESSt, to estimate true corneal power after keratorefractive surgery in eyes requiring cataract surgery. SETTING Moorfields Eye Hospital, London, United Kingdom. METHODS The BESSt formula, based on the Gaussian optics formula, was developed using data from 143 eyes that had keratorefractive surgery. The formula takes into account anterior and posterior cor...
متن کاملIntraocular lens power calculation using standard formulas and ray tracing after DMEK in patients with Fuchs endothelial dystrophy
BACKGROUND The study presented here aims to optimize the accuracy of intraocular lens (IOL) power calculations in patients after DMEK by evaluation of the impact of the altered anterior/posterior corneal curvature relationship. METHODS Scheimpflug-based Oculus Pentacam imaging was performed after DMEK surgery for Fuchs endothelial dystrophy. The IOL power was calculated for all patients by ra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 59 2 شماره
صفحات -
تاریخ انتشار 2018