An in vivo comparison of the efficacy of hemostatic powders, using two porcine bleeding models

نویسندگان

  • Melinda H MacDonald
  • Allen Y Wang
  • Jeffrey W Clymer
  • Richard W Hutchinson
  • Richard Kocharian
چکیده

Background Usage of topical hemostatic agents in surgery is increasing, including use during minimally invasive procedures, and even for surgeries that have a low risk of bleeding complications. A novel product, Surgicel® Powder - Absorbable Hemostatic Powder (SP), made from oxidized regenerated cellulose (ORC) fabric, has been developed for adjunctive use in surgical procedures to assist in control of oozing bleeding over broad areas and where access could be difficult with a fabric ORC product. This study compares the new SP to other commercially available hemostatic powder products in two in vivo models. Methods Hemostatic efficacy of SP was compared to two polysaccharide-based hemostats in a porcine liver punch biopsy model and to three polysaccharide-based hemostats and one non-regenerated oxidized cellulose hemostat in a porcine liver abrasion model. Primary outcomes measured were hemostatic efficacy, defined as hemostasis within 10 minutes of application, and time-to-hemostasis (TTH). Results In the punch biopsy model, SP displayed significantly higher effective hemostasis rates than one of the polysaccharide hemostats (p=0.047) and faster TTH than both (p<0.001). In the liver abrasion model, SP had significantly higher effective hemostasis rates (p≤0.002) and faster TTH (p<0.001) than the other four hemostatic agents. The amount of powder applied within the ranges used did not appear to affect hemostatic efficacy. Conclusion In both the liver punch biopsy model of mild to moderate bleeding and the liver abrasion model of mild but diffuse oozing, SP provided more effective hemostasis and faster TTH than other marketed hemostatic powders. The results from this in vivo study suggest that Surgicel Powder may be useful in clinical applications where control of oozing capillary, mild venous, and small arterial hemorrhage is required including bleeding in difficult-to-access locations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه اثر کلسیم سولفات و کلرید فریک در کنترل خونریزی طی جراحی کبدی؛ مطالعه مدل حیوانی

Background and Objective: The control of parenchymal hemorrhage especially in liver parenchyma, despite improvements in surgical science, is still one of the challenges that surgeons are facing with. Therefore, introducing an effective method to control liver bleeding is of important research priority. This study aimed to compare the hemostatic effect of calcium sulfate and ferric chloride on c...

متن کامل

Efficacy of forced coagulation with low high-frequency power setting during endoscopic submucosal dissection

AIM To investigated the hemostatic ability of the S and F1-10 methods in clinical and ex vivo studies. METHODS The hemostatic abilities of the two methods were analyzed retrospectively in all six gastric endoscopic submucosal dissection cases. The treated vessel diameter, compressed vessel frequency, and bleeding frequency after cutting the vessels were noted by the recorded videos. The coagu...

متن کامل

The effect of acid modification of porcine mucin on its drug release and skin permeation properties in insulin transdermal patches

The study aimed at determining the effect of acid modified porcine mucin powder on the release and permeation of insulin in transdermal patches. Various batches of insulin patches were prepared by solvent casting method using polysorbate 80 as emulsifying agent and acid treated and untreated mucin powders as base. The patches were evaluated for their physical properties, folding endurance, moi...

متن کامل

Review on Effect of Hemorrhages in Rescuing Casualties from Fatalities

Introduction: High bleeding due to hypolemia may cause early death. If injured persons hospitalized due to trauma, they may more likely to die. Methods for bleeding control include mechanical, heat treatment, drug therapy, or topical hemostats. The purpose of this study was to evaluate the efficacy of hemorrhage and their usages in all emergency bleeding cases (in the years of 2008-2019). In t...

متن کامل

Comparison of Two Gelatin and Thrombin Combination Hemostats in a Porcine Liver Abrasion Model

BACKGROUND Surgical hemostasis is achieved using adjunctive hemostats when conventional methods fail. OBJECTIVE This study compares the effectiveness of two adjunctive gelatin-thrombin hemostats. HYPOTHESIS To determine effectiveness, hemostats were compared in vivo, in vitro, and using scanning electron microscopy (SEM). METHODS In vivo, a heparinized porcine liver abrasion model was use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017