Long term outcome and quality of life after open incisional hernia repair - light versus heavy weight meshes
نویسندگان
چکیده
BACKGROUND Mesh repair of incisional hernia is superior to the conventional technique. From all available materials for open surgery polypropylene (PP) is the most widely used. Development resulted in meshes with larger pore size, decreased mesh surface and lower weight. The aim of this retrospective non randomized study was to compare the quality of life in the long term follow up (> 72 month) after incisional hernia repair with "light weight"(LW) and "heavy weight"(HW) PP meshes. METHODS 12 patients who underwent midline open incisional hernia repair with a HW-PP mesh (Prolene® 109 g/m2 pore size 1.6 mm) between January 1996 and December 1997 were compared with 12 consecutive patients who underwent the same procedure with a LW-PP mesh (Vypro® 54 g/m2, pore size 4-5 mm) from January 1998. The standard technique was the sublay mesh-plasty with the retromuscular positioning of the mesh. The two groups were equal in BMI, age, gender and hernia size. Patients were routinely seen back in the clinic. RESULTS In the long term run (mean follow up 112 ± 22 months) patients of the HW mesh group revealed no significant difference in the SF-36 Health Survey domains compared to the LW group (mean follow up 75 ± 16 months). CONCLUSIONS In this study the health related quality of life based on the SF 36 survey after open incisional hernia repair with light or heavy weight meshes is not related to the mesh type in the long term follow up.
منابع مشابه
Light weight meshes in incisional hernia repair
Incisional hernias remain one of the most common surgical complications with a long-term incidence of 10-20%. Increasing evidence of impaired wound healing in these patients supports routine use of an open prefascial, retromuscular mesh repair. Basic pathophysiologic principles dictate that for a successful long-term outcome and prevention of recurrence, a wide overlap underneath healthy tissue...
متن کاملA randomised, multi-centre, prospective, double blind pilot-study to evaluate safety and efficacy of the non-absorbable Optilene® Mesh Elastic versus the partly absorbable Ultrapro® Mesh for incisional hernia repair
BACKGROUND Randomised controlled trials with a long term follow-up (3 to 10 years) have demonstrated that mesh repair is superior to suture closure of incisional hernia with lower recurrence rates (5 to 20% versus 20 to 63%). Yet, the ideal size and material of the mesh are not defined. So far, there are few prospective studies that evaluate the influence of the mesh texture on patient's satisf...
متن کاملQuality of Life after Suture Repair for Incisional Hernia: Long-term Postoperative and Retrospective Preoperative Evaluations
urpose: The aim of this observational study was to examine postoperative and retrospective preoperative evaluations of multiple dimensions of patient quality of life after a threelayered closure repair for incisional hernia. Methods: After suture repair of an incisional hernia (mean follow-up of 4.6 years), 72 patients (32 female, 40 male, mean age 63.6 years) completed the SF-36 Health Survey ...
متن کاملThe INCH-Trial: a multicentre randomized controlled trial comparing the efficacy of conventional open surgery and laparoscopic surgery for incisional hernia repair
BACKGROUND Annually approximately 100.000 patients undergo a laparotomy in the Netherlands. About 15,000 of these patients will develop an incisional hernia. Both open and laparoscopic surgical repair have been proven to be safe. However, the most effective treatment of incisional hernias remains unclear. This study, the 'INCH-trial', comparing cost-effectiveness of open and laparoscopic incisi...
متن کاملMesh versus non-mesh repair of ventral abdominal hernias.
BACKGROUND To investigate the relative effectiveness of mesh and suture repair of ventral abdominal hernias in terms of clinical outcome, quality of life and rate of recurrence in both the techniques. METHODS This is a retrospective descriptive analysis of 236 patients with mesh and non-mesh repair of primary ventral hernias performed between January 2000 to December 2004 at Surgery Departmen...
متن کامل