A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)

نویسندگان

  • Shiva Keihaninejad
  • Rolf A. Heckemann
  • Gianlorenzo Fagiolo
  • Mark R. Symms
  • Joseph V. Hajnal
  • Alexander Hammers
چکیده

As population-based studies may obtain images from scanners with different field strengths, a method to normalize regional brain volumes according to intracranial volume (ICV) independent of field strength is needed. We found systematic differences in ICV estimation, tested in a cohort of healthy subjects (n=5) that had been imaged using 1.5T and 3T scanners, and confirmed in two independent cohorts. This was related to systematic differences in the intensity of cerebrospinal fluid (CSF), with higher intensities for CSF located in the ventricles compared with CSF in the cisterns, at 3T versus 1.5T, which could not be removed with three different applied bias correction algorithms. We developed a method based on tissue probability maps in MNI (Montreal Neurological Institute) space and reverse normalization (reverse brain mask, RBM) and validated it against manual ICV measurements. We also compared it with alternative automated ICV estimation methods based on Statistical Parametric Mapping (SPM5) and Brain Extraction Tool (FSL). The proposed RBM method was equivalent to manual ICV normalization with a high intraclass correlation coefficient (ICC=0.99) and reliable across different field strengths. RBM achieved the best combination of precision and reliability in a group of healthy subjects, a group of patients with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and can be used as a common normalization framework.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robustness of Automated Methods for Brain Volume Measurements across Different MRI Field Strengths

INTRODUCTION Pooling of multicenter brain imaging data is a trend in studies on ageing related brain diseases. This poses challenges to MR-based brain segmentation. The performance across different field strengths of three widely used automated methods for brain volume measurements was assessed in the present study. METHODS Ten subjects (mean age: 64 years) were scanned on 1.5T and 3T MRI on ...

متن کامل

Effects of combining field strengths on auditory functional MRI group analysis: 1.5T and 3T.

PURPOSE To evaluate effects of combining functional magnetic resonance imaging (fMRI) data acquired from different field strengths on group analysis as a function of the number of subjects at each field strength. MATERIALS AND METHODS In all, 28 subjects (18 at 3T) participated in an auditory task of passively listening to a 0.75s segment of jazz music in an event-related design. Results of s...

متن کامل

White Matter Hyperintensities on 1.5 and 3 Tesla Brain MRI in Healthy Individuals

Background: White matter hyperintensities (WMH) on T2-weighted magnetic resonance imaging (MRI) are frequent incidental findings in brains of asymptomatic healthy individuals (HI). The morphological and spatial distribution of these WMH between standard 1.5T scanners and increasingly available 3T scanners in a large population of HI in clinical routine settings has not been investigated. Object...

متن کامل

Automated segmentation of cerebral deep gray matter from MRI scans: effect of field strength on sensitivity and reliability

BACKGROUND The cerebral subcortical deep gray matter nuclei (DGM) are a common, early, and clinically-relevant site of atrophy in multiple sclerosis (MS). Robust and reliable DGM segmentation could prove useful to evaluate putative neuroprotective MS therapies. The objective of the study was to compare the sensitivity and reliability of DGM volumes obtained from 1.5T vs. 3T MRI. METHODS Fourt...

متن کامل

Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: Radiofrequency-induced heating

PURPOSE To investigate heating during postimplantation localization of intracranial electroencephalograph (EEG) electrodes by MRI. MATERIALS AND METHODS A phantom patient with a realistic arrangement of electrodes was used to simulate tissue heating during MRI. Measurements were performed using 1.5 Tesla (T) and 3T MRI scanners, using head- and body-transmit RF-coils. Two electrode-lead confi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2010