Epidemiology of spirometric test failure.

نویسنده

  • M R Becklake
چکیده

Excessive variability in spirometric measurements derived from the forced expiratory volume manoeuvre , also called "test failure,"' is a phenomenon familiar to all those who use pulmonary function tests, whether it be in a clinical context2 or in the context of population based studies.3 Because the manoeuvre is effort dependent, test failure is usually attributed to a failure of effort or comprehension on the part of the patient or subject (one editorialist capsulised the issue in the phrase "disability or disinclination")4 or to the incompetence of the technician .256 Adequate effort on the part of the subject tends to be particularly in question in disability assessments or when workmens' compensation is involved.4 To counter this, guidelines have been developed to standardise spirometry, both in the clinical and the epidemiological context.7 In addition to technical recommendations on equipment, its selection and validation, these guidelines recommend that a minimum of three satisfactorily performed trials should be required from a subject undergoing tests (criteria for satisfactory performance are clearly defined), with up to eight trials if this is necessary to meet certain reproducibility criteria.56 For FEV, and FVC, the reproducibility criteria recommended by the American Thoracic Society are that the two best trials should not differ by more than 5% or 100 ml, whichever is the greater6; those recommended by the European Economic Community stipulate that the difference should not exceed 300 ml for FVC.' The purpose of this editorial is to bring to attention the gathering evidence, mostly from epidemiological studies in industry, that failure to perform reproducible spirometry may itself be an indicator of respiratory ill health. For instance, in several cross sectional studies of occupational groups test failure has been shown to relate to symptoms.89 In Chinese textile workers the symptoms were those of byssin-osis,8 in Pennsylvania railroad workers chronic bronchitis ,8 and in coal miners, wheezing and shortness of breath were implicated as well as chronic cough and sputum.9 Similarly, subjects who exhibit test failure have, on average, lower levels of FEV,910 and an increased annual loss of FEV, in two cohort studies in which this has been measured.''O Test failure does not, however, appear to be a significant predictor of death when function level and smoking are taken into account.91O A surprising and unexplained feature in two community based studies was that test failure occurred less frequently in smokers than in non-smokers.'"1 The physiological mechanisms underlying the phenomenon …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis

Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50  pa...

متن کامل

Long-term Follow-up Study of Pulmonary Function Test in Children with History of Hydrocarbon Aspiration

Background Aspiration of hydrocarbons causes several acute and chronic pulmonary complications; it may even lead to death. The aim of this study was to investigate the types of long-term pulmonary complications in children with a history of hydrocarbon aspiration. Materials and Methods In this case-control study, 21 children ...

متن کامل

Pulmonary function test abnormalities in the elderly with systolic heart failure.

BACKGROUND An association between chronic heart failure (CHF) and pulmonary function abnormalities is clinically important. Spirometry is frequently used to evaluate lung function. AIM To evaluate some spirometric parameters in the elderly with newly diagnosed or known systolic CHF. METHODS The study group consisted of 110 patients (74 men-67.3%) who underwent echocardiography as well as sp...

متن کامل

Spirometric evaluation of pulmonary function in Yazd’s dental laboratory workers in 1398

​abstract Introduction: Spirometry is a common device screening in occupational pulmonary disease. Dental laboratory workers usually are exposed to vapor, toxic gases, dust, metallic alloys, acrylics, and stones. Aim of This study was a Spirometric evaluation of the pulmonary function of Yazd’s dental laboratory workers. Method and materials: in this cross-sectional study 37 Yazd’dental tech...

متن کامل

An approach to interpreting restrictive spirometric pattern results in occupational settings.

OBJECTIVES The aim of this review is to provide an updated overview of definition, epidemiology, diagnostic algorithm and occupational exposures related to abnormal restrictive spirometrical pattern (RSP) in order to improve the correct interpretation of spirometry test results by occupational healthcare providers. METHODS A review of the scientific English literature of the last 25 years was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 1990