Development of transplantation vasculopathy and progression of donor-transmitted atherosclerosis: comparison by serial intravascular ultrasound imaging.
نویسندگان
چکیده
BACKGROUND Transplant coronary artery disease is a combination of atherosclerosis transmitted from the donor and new lesions of allograft vasculopathy. We sought to determine the morphological characteristics of allograft vasculopathy and differentiate it from donor-transmitted atherosclerosis with serial intravascular ultrasound. METHODS AND RESULTS Intravascular ultrasound examination was performed in 93 patients at 27.2+/-15.0 and 369. 7+/-23.9 days after transplantation. The maximally and minimally diseased sites were selected in each segment as defined by Coronary Artery Surgery Study classification. For each matched site, maximal plaque thickness was measured. Lesions (maximum plaque thickness >/=0.5 mm) present at baseline examination were defined as donor lesions. On follow-up, lesions that developed at previously normal sites were defined as de novo lesions. The distribution and severity of donor and de novo lesions were similar in proximal, mid, and distal segments. The de novo lesions were less focal (43% vs 74%) and more circumferential (69% vs 45%) compared with the donor lesions, but there was significant morphological heterogeneity. Similar numbers of patients with and those without donor lesions developed de novo lesions. Moreover, progression of donor lesions was not associated with the presence or absence of de novo lesions. CONCLUSIONS Differentiation between early allograft vasculopathy from conventional atherosclerosis by distribution and morphology of lesions alone is difficult. Serial intravascular ultrasound imaging with early baseline examination is necessary to make this distinction. This distinction is important because the progression of donor lesions and the development of de novo lesions are independent of each other.
منابع مشابه
Impact of lipid abnormalities in development and progression of transplant coronary disease: a serial intravascular ultrasound study.
OBJECTIVES We sought to determine the role of conventional atherosclerosis risk factors in the development and progression of transplant coronary artery disease (CAD) using serial intravascular ultrasound imaging. BACKGROUND Transplant artery disease is a combination of allograft vasculopathy and donor atherosclerosis. The clinical determinants for each of these disease processes are not well...
متن کاملDonor-Transmitted Atherosclerosis Associated With Worsening Cardiac Allograft Vasculopathy After Heart Transplantation: Serial Volumetric Intravascular Ultrasound Analysis
BACKGROUND The influence of preexisting donor-transmitted atherosclerosis (DA) on cardiac allograft vasculopathy (CAV) development remains unclear. METHODS We performed 3-dimensional intravascular ultrasound (3D-IVUS) analysis in 42 heart transplantation (HTx) recipients at 2.1 ± 0.9 months (baseline) and 12.2 ± 0.4 months post-HTx, as well as consecutive 3D-IVUS analyses up to 3 years post-H...
متن کاملRegression of a donor atheroma after cardiac transplantation: serial observations with intravascular ultrasound.
A42-year-old man received a cardiac transplantation in October 1995 for dilated cardiomyopathy. He had no history of hyperlipidemia or coronary artery disease. The heart donor was a 41-year-old woman with a history of hypertension. The first intravascular ultrasound (IVUS) study was obtained 14 days after cardiac transplantation, and the last follow-up examination was performed 5 years later. F...
متن کاملImpact of donor-transmitted atherosclerosis on early cardiac allograft vasculopathy: new findings by three-dimensional intravascular ultrasound analysis.
BACKGROUND The influence of donor-transmitted coronary atherosclerosis (DA) on plaque progression during the first year after cardiac transplantation (Tx) is unknown. METHODS Serial 3-dimensional intravascular ultrasound (IVUS) studies were performed within 8 weeks (baseline; BL) and at 1 year after Tx in 38 recipients. On the basis of maximum intimal thickness (MIT) at BL, recipients were di...
متن کاملIntravascular ultrasound evidence of angiographically silent progression in coronary atherosclerosis predicts long-term morbidity and mortality after cardiac transplantation.
OBJECTIVES The aim of this study was to determine whether angiographically silent early coronary intimal thickening could predict long-term morbidity and mortality. BACKGROUND Although intravascular ultrasound (IVUS) is widely used to detect early transplant coronary disease, its prognostic significance has not been well defined. METHODS The study cohort consisted of 143 patients who underw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 98 24 شماره
صفحات -
تاریخ انتشار 1998