Determination of aflatoxins B1 and B2 using ion mobility spectrometry.
نویسندگان
چکیده
This paper describes total determination of aflatoxins B1 and B2 in pistachio samples using corona discharge ion mobility spectrometry (IMS). A new injection port was designed to introduce liquid samples into the IMS. Using this port, the liquid solvent (methanol) containing standard aflatoxins or an extracted sample was directly introduced into the injection port. Calibration curves resulting from experimental analyses were linear within two orders of magnitude and relative standard deviations (R.S.D.) were less than 10%. The limit of detection (LOD) was found to be 0.25 ng for both aflatoxins. Addition of ammonia as the dopant to the carrier gas improved the LOD by a factor of 2.5. Pistachio samples were analyzed to demonstrate the capability of the proposed method in detecting aflatoxins in real samples.
منابع مشابه
Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method
Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...
متن کاملIdentification and Quantitation of four Aflatoxins using the Bruker amaZon SL Ion Trap Mass Spectrometer
Aflatoxins are a type of mycotoxin that are toxic and extremely carcinogenic. Food for human consumption and feed for livestock are routinely tested for their presence. A sensitive analytical method for the determination and quantitation of four aflatoxins using the Bruker amaZon SL Ion Trap mass spectrometry system is presented here. Specifically, this method uses LC/MS/MS to quantify aflatoxi...
متن کاملDetection of Aflatoxin B1, B2, G1 and G2 in Rhizosphere and Rhizosplane of (zea Mays) Maize Plants Using Liquid Chromatography – Mass Spectrometry
An easy method for the determination of aflatoxins B1, B2, G1, and G2 in rhizosphere and rhizosplane of zea mays by LC coupled to mass spectrometry had been developed. Aflatoxins B1, B2, G1 and G2 in maize plants by LC coupled to mass spectrometry had been developed. Aflatoxins were extracted with a mixture of methanol and water and then it was purified by solid – phase clean – up using a polym...
متن کاملIdentification of aflatoxins by quadrupole mass spectrometry/mass spectrometry.
MS/MS daughter experiments were recorded for aflatoxins B1, B2, G1, G2, M1, M2, and aflatoxicol, using 3 ionization modes. Daughters were recorded from the molecular ion (M+) using electron impact ionization (EI). Daughters from the protonated molecules (MH+) were recorded in the positive ion mode and the daughters from the molecular anion (M-) were recorded in the negative ion mode using chemi...
متن کاملApplication of Ion Mobility Spectrometry for Determination of Morphine in Human Urine
In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 75 1 شماره
صفحات -
تاریخ انتشار 2008