Real-time three-dimensional transesophageal echocardiography to predict artificial chordae length for mitral valve repair

نویسندگان

  • Huan-lei Huang
  • Xu-jing Xie
  • Hong-wen Fei
  • Xue-jun Xiao
  • Jing Liu
  • Jian Zhuang
  • Cong Lu
چکیده

BACKGROUND Artificial chordae replacement is an effective technique for mitral valve repair, however, it is difficult to accurately determine the length of artificial chordae. This study aimed to assess the reliability and accuracy of real-time three-dimensional transesophageal echocardiography (TEE) to predict the length of artificial chordae preoperatively. METHODS From December 2008 to December 2010, 48 patients with severe mitral regurgitation successfully underwent mitral valve repair using artificial chordae replacement. The patients were divided into a TEE pre-measurement group (n = 26) and a direct measurement group (n = 22), according to the method used to determine the length of artificial chordae. Cardiopulmonary bypass time, aortic cross-clamp time, and the recurrence rate of moderate or severe mitral regurgitation were compared between the two groups. RESULTS There were no operative deaths in either group. The mean cardiopulmonary bypass time was 113.0 ± 18.7 min and 127.0 ± 28.9 min (p < 0.05), and the aortic cross-clamp time was 70.0 ± 16.6 min and 86.0 ± 20.7 min (p < 0.05) in the TEE pre-measurement group and direct measurement group, respectively. The difference between the pre-measured artificial chordal length and actual constructed artificial chordal length was not significant in the TEE pre-measurement group (p > 0.05). Although the difference in the incidence of moderate or severe mitral regurgitation between the two groups was not significant (p > 0.05), the incidence in the TEE pre-measurement group (3.8%) was lower than that in the direct measurement group (18.2%). CONCLUSIONS Real-time three-dimensional transesophageal echocardiography can accurately predict the length of artificial chordae required for mitral valve repair, and shortens cardiopulmonary bypass time and aortic cross-clamp time while improving the results of mitral valve repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of real time two-dimensional with live/real time three-dimensional transesophageal echocardiography in the evaluation of mitral valve prolapse and chordae rupture.

We compared live/real time three-dimensional transesophageal echocardiography (3D TEE) with real time two-dimensional transesophageal echocardiography (2D TEE) in the assessment of individual mitral valve (MV) segment/scallop prolapse and associated chordae rupture in 18 adult patients with a flail MV undergoing surgery for mitral regurgitation. 2D TEE was able to diagnose the prolapsing segmen...

متن کامل

Neochordameter: A New Technology in Mitral Valve Repair

BACKGROUND Mitral valve repair has shown superior results compared to mitral valve replacement in patients with mitral valve prolapse. Using premeasured neochordae (the loop technique) has been proposed for both anterior and posterior leaflet repairs. However, there are two major problems that are usually experienced using this method. One is deciding the length of the neo-chordae, and the othe...

متن کامل

Real-time 3-dimensional transesophageal echocardiography: precise evaluation of a rocking mitral annuloplasty ring.

A 48-year-old man with a medical history of hypertension was admitted with acute dyspnea and pyrexia. Echocardiographic examination revealed a dilated and volumeoverloaded left ventricle and severe mitral regurgitation due to ruptured chordae tendinae resulting in posterior leaflet prolapse. Blood cultures were negative. The patient was treated with antibiotics considering that he had a chest i...

متن کامل

Usefulness of intraoperative real-time three-dimensional transesophageal echocardiography for pre-procedural evaluation of mitral valve cleft: a case report

A precise pre-procedural evaluation of mitral valve (MV) pathology is essential for planning the surgical strategy for severe mitral regurgitation (MR) and preparing for the intraoperative procedure. In the present case, a 38-year-old woman was scheduled to undergo MV replacement due to severe MR. She had a history of undergoing percutaneous balloon valvuloplasty due to rheumatic mitral stenosi...

متن کامل

Papillary fibroelastoma of a mitral valve chordae, presenting with atypical chest pain and palpitation: A case report and the literature

Background: Primary intra cardiac tumors are rare. In this article, we present papillary fibroelastoma of mitral valve chordae. Case Presentation: A 35-year old man presented with atypical chest pain and palpitation. Physical examination and electrocardiogram were normal. Transesophageal echocardiography (TEE) revealed a mass of 1015 mm attached to chordae of anteromedial papillary muscle of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013