Sensitive electrochemical immunosensor array for the simultaneous detection of multiple tumor markers.

نویسندگان

  • Honglan Qi
  • Chen Ling
  • Qingyun Ma
  • Qiang Gao
  • Chengxiao Zhang
چکیده

A novel electrochemical immunosensor array for the simultaneous detection of multiple tumor markers was developed by incorporating electrochemically addressing immobilization and one signal antibody strategy. As a proof-of-principle, an eight-electrode array including six carbon screen-printed working electrodes was used as a base array for the analysis of two important tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) and a horseradish peroxidase-labeled antibody was employed as a signal antibody. The immunosensor in the array was fabricated in sequence by covalently coupling the capture antibody onto the surface of the desired working electrode, which was firstly electrochemically addressably grafted with an aminophenyl group by reduction of in situ generated aminophenyl diazonium cation generated from p-phenylenediamine, using glutaraldehyde as cross-linker. This allowed the selective immobilization of the capture antibody at the desired position on a single array via an electrochemical operation. The immunoassay in sandwich mode was performed by specifically binding the targets, second antibodies and one signal antibody to the immunosensor array. The result showed that the steady current density was directly proportional to the concentration of target CEA/AFP in the range from 0.10 to 50 ng mL(-1) with a detection limit of 0.03 ng mL(-1) for CEA and 0.05 ng mL(-1) for AFP (S/N = 3), respectively. This work demonstrates that the employment of an electrochemically addressing method for the fabrication of an immunosensor array and one signal antibody is a promising approach for the determination of multiple tumor markers in clinical samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface

An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...

متن کامل

A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.

BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetopr...

متن کامل

Electrochemical stripping analysis of nanogold label-induced silver deposition for ultrasensitive multiplexed detection of tumor markers.

A multiplexed electrochemical immunoassay method was developed for simultaneous ultrasensitive measurement of tumor markers based on electrochemical stripping analysis of silver nanoparticles (Ag NPs). The Ag NPs were deposited on a disposable immunosensor array with a reduction reaction catalyzed by nanogold labels. The immunosensor array was prepared by covalently immobilizing capture antibod...

متن کامل

Disposable reagentless electrochemical immunosensor array based on a biopolymer/sol-gel membrane for simultaneous measurement of several tumor markers.

BACKGROUND A reagentless sensor array for simultaneous multianalyte testing (SMAT) may enable accurate diagnosis and be applicable for point-of-care testing. We developed a disposable reagentless immunosensor array for simple immunoassay of panels of tumor markers. METHODS We carried out SMAT with a direct capture format, in which colloidal gold nanoparticles with bound horseradish peroxidase...

متن کامل

Dual signal amplification of glucose oxidase-functionalized nanocomposites as a trace label for ultrasensitive simultaneous multiplexed electrochemical detection of tumor markers.

A novel tracer, glucose oxidase-functionalized nanocomposite, was designed to label the signal antibodies for ultrasensitive multiplexed measurement of tumor markers using a disposable immunosensor array. The immunosensor array was constructed by coating layer-by-layer colloidal Prussian blue (PB), gold nanoparticles, and capture antibodies on screen-printed carbon electrodes. The preparation o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 137 2  شماره 

صفحات  -

تاریخ انتشار 2012