St. Jude Medical Trifecta™ aortic valve perioperative performance in 200 patients.

نویسندگان

  • Eduard Permanyer
  • Arnaldo-Javier Estigarribia
  • Alejandro Ysasi
  • Enrique Herrero
  • Omar Semper
  • Rafael Llorens
چکیده

OBJECTIVES The St. Jude Medical Trifecta aortic bioprosthesis (St. Jude Medical, Inc., St. Paul, MN, USA) is a new stented pericardial tissue heart valve. The aim of the study was to evaluate the clinical and haemodynamic performance of the Trifecta bioprosthesis in the early postoperative period. METHODS From July 2010 to September 2012, a total of 200 consecutive patients underwent aortic valve replacement with the Trifecta valve in our institution. All intraoperative and postoperative data were prospectively collected. Mean EuroSCORE II was 3.98%. Echocardiography was performed at discharge in all patients. RESULTS The mean age was 71.2 ± 7.7 (range 39-89 years). Extubation in the operating theatre was successfully performed in 96% of patients. Mean hospital stay was 8.5 days. The prosthesis sizes were 19 mm (n = 33), 21 mm (n = 81), 23 mm (n = 59), 25 mm (n = 23) and 27 mm (n = 4). Mean systolic pressure gradients ranged from 9.4 mmHg (size 19 valve) to 4.8 mmHg (size 27 valve). Mean effective orifice area (EOA) ranged from 1.61 cm(2) (size 19 valve) to 2.5 cm(2) (size 27 valve). Severe mismatch (<0.65 cm(2)/m(2)) did not occur in any patient. Of note, 99.5% of patients had mild or no aortic insufficiency at discharge. The early (30-day) mortality was 2.5% (n = 5). CONCLUSIONS The Trifecta valve offers good clinical results and excellent haemodynamic performance. Special care must be taken to avoid oversizing, which can lead to difficulty in implantation and can produce gradient increases due to an excess of prosthetic leaflet tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midterm Follow-Up of Haemodynamic Performance of the St. Jude Medical Trifecta Aortic Bioprosthesis in Young Patients Under 65

Method Thirty consecutive patients undergoing aortic valve replacement using the St. Jude Medical Trifecta valve at a single UK centre over a 48-month period were included in this study. Patients undergoing concomitant cardiac procedures were included. All implanted valves were 21, 23, 25 and 27 mm in size. Assessment of haemodynamic function was carried out using transthoracic echocardiography...

متن کامل

The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study.

BACKGROUND The St Jude Medical Inc (St Paul, Minn) Trifecta valve is a novel aortic biological prosthesis that incorporates several design features, including a true supra-annular sewing cuff, a stent design that maximizes valve hemodynamics while minimizing leaflet stresses, and an ethanol-based anticalcification technology. This study establishes the safety and early clinical and hemodynamic ...

متن کامل

Left Ventricular Mass Regression following Implantation of St. Jude Medical Trifecta Aortic Bioprosthesis

Method One hundred and seventy two consecutive patients undergoing aortic valve replacement using the St. Jude Medical Trifecta valve at a single UK centre over a 48-month period were included in this study. Patients undergoing concomitant cardiac procedures were included. All implanted valves were 19, 21, 23, 25, 27 & 29 mm in size. Patients underwent both pre-operative and post-operative tran...

متن کامل

St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry

BACKGROUND The Trifecta aortic bioprosthesis (St. Jude Medical, Inc., St. Paul, MN, USA) is a stented pericardial heart valve with excellent preliminary results. Aim of the study was to evaluate its early clinical and hemodynamic performances in a multicenter regional registry. METHODS Between January 2011 and June 2012, 178 consecutive patients undergoing aortic valve replacement with the Tr...

متن کامل

Matched Comparison of Two Different Biological Prostheses for Complete Supra-annular Aortic Valve Replacement.

Objective The aim of this retrospective study was to evaluate the hemodynamic performance of the St. Jude Medical Trifecta (SJM Trifecta; St. Jude Medical, St Paul, Minnesota, United States) and the Carpentier-Edwards Perimount Magna Ease (CEPM Ease; Edwards Lifesciences, Irvine, California, United States) bioprostheses early postoperative and at 1 year. Methods From October 2007 to October 200...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2013