Endocardial catheter mapping: validation of a cineradiographic method for accurate localization of left ventricular sites.
نویسندگان
چکیده
To guide surgical therapy for ventricular tachycardia by preoperative endocardial catheter mapping, accurate anatomic localization of arrhythmogenic sites is mandatory. For this reason we developed a mathematical cineradiographic method to compute left ventricular sites relative to three anatomic reference points: the centers of aortic and mitral valve ostia and the left ventricular apex. To validate the method 14 epicardial left ventricular markers were implanted in four dogs to simulate arrhythmogenic sites. Distances between markers and the anatomic references were calculated and the results were compared with postmortem measurements. The difference between calculated and measured distances was 0.5 +/- 3.1 mm (mean +/- SD), confirming accurate localization of anatomic marker sites. However, in surgery the results have to be displayed in a practically applicable, unambiguous way. Therefore, wire skeletons were constructed to represent calculated endocardial marker sites relative to the anatomic reference points. To validate this approach, 14 markers were implanted in the left ventricular subendocardium in four dogs. Wire skeletons were constructed, one for each marker site, and inserted postmortem into the left ventricular cavity via a 2 cm incision. In all cases the correct indication of a marker site by the corresponding wire skeleton was confirmed by fluoroscopic inspection in multiple projections. This wire skeleton technique may enhance the practical usefulness of preoperative endocardial catheter mapping.
منابع مشابه
Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium.
BACKGROUND Improvements in cardiac mapping are required to advance our understanding and treatment of arrhythmias. This study validated a new noncontact multielectrode array catheter and accompanying analysis system to provide electroanatomic mapping of the entire left ventricular (LV) endocardium during a single beat. METHODS AND RESULTS A 9F 64-electrode balloon array catheter with an infla...
متن کاملLocalization of the Site of Origin of Postinfarction Ventricular Tachycardia by Endocardial Pace Mapping
Background. The purpose of this study was to assess the value of body surface mapping and the standard 12-lead ECG in localizing the site of origin of postinfarction ventricular tachycardia (VT) during endocardial pace mapping of the left ventricle. Methods and Results. Simultaneous recordings of 62-lead body surface QRS integral maps and scalar 12-lead ECG tracings were obtained in 16 patients...
متن کاملLocalization of the site of origin of postinfarction ventricular tachycardia by endocardial pace mapping. Body surface mapping compared with the 12-lead electrocardiogram.
BACKGROUND The purpose of this study was to assess the value of body surface mapping and the standard 12-lead ECG in localizing the site of origin of postinfarction ventricular tachycardia (VT) during endocardial pace mapping of the left ventricle. METHODS AND RESULTS Simultaneous recordings of 62-lead body surface QRS integral maps and scalar 12-lead ECG tracings were obtained in 16 patients...
متن کاملThe echo-transponder electrode catheter: a new method for mapping the left ventricle.
The ability to locate catheter position in the left ventricle with respect to endocardial landmarks might enhance the accuracy of ventricular tachycardia mapping. An echo-transponder system (Telectronics, Inc.) was compared with biplane fluoroscopy for left ventricular endocardial mapping. A 6F electrode catheter was modified with the addition of a piezoelectric crystal 5 mm from the tip. This ...
متن کاملThe Use of Simultaneous Multichannel Endocardial and Surface Electrocardiograms for Verification of Exit Site Localization Using Body Surface Mapping
Exit sites of monomorphic ventricular tachycardia and focal sites of ventricular extrasystoles can be localized using an endocardial catheter in conjunction with a multichannel surface ECG, in order to find a suitable site for ablation. For this procedure, as well as for the diagnosis of these types of arrhythmia it is desirable to know the relation between surface ECG and site of origin accura...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 74 4 شماره
صفحات -
تاریخ انتشار 1986