A multiple-contact EMG recording array for mapping single muscle unit territories.

نویسندگان

  • C M Chanaud
  • C A Pratt
  • G E Loeb
چکیده

The glycogen-depletion technique has become a well-established method for determining histologically the cross-sectional distribution of a single muscle unit. A major drawback of this method is its low yield of one depleted unit per experiment. Furthermore, this technique is particularly unsuited for determining the longitudinal distribution of single muscle units in long, broad muscles because of the formidable serial sectioning job that would be required. Our alternative, electrophysiological method utilizes a multiple-contact, two-dimensional EMG recording array to map efficiently the cross-sectional and longitudinal distributions of numerous single muscle units in anatomically diverse muscles. Additionally, architectural information on muscle fiber lengths, end-plate locations, motor subunit (MSU) arrangements and muscle conduction velocities can be determined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional model of a muscle and simulation of its surface EMG

The aim of this paper was to present a spatial model of a muscle including all its motor units (MU) and a simulation of its surface EMG. The simulations are part of a larger model including in addition the input system to the motoneuronal pool, the motoneuronal pool itself and the force generating mechanism. The muscle and the MU territories are represented by elliptic cylinders. Two algorithms...

متن کامل

Multichannel surface EMG for the non-invasive assessment of the anal sphincter muscle.

BACKGROUND/AIMS This work focuses on recording, processing and interpretation of multichannel surface EMG detected from the external anal sphincter muscle. The aim is to describe the information that can be extracted from signals recorded with such a technique. METHODS The recording of many signals from different locations on a muscle allows the extraction of additional information on muscle ...

متن کامل

[Article] Multichannel Surface EMG for the Non-Invasive Assessment of the Anal Sphincter Muscle

Background/Aims: This work focuses on recording, processing and interpretation of multi-channel surface EMG detected from the external anal sphincter muscle. The aim is to describe the information that can be extracted from signals recorded with such a technique. Methods: The recording of many signals from different locations on a muscle allows the extraction of additional information on muscle...

متن کامل

Macro EMG, a new recording technique.

A new electromyographic technique for the study of the motor unit is described. A modified single fibre EMG electrode is used. The electrical activity obtained by the electrode shaft during voluntary muscle contraction is averaged after triggering from a single muscle fibre action potential and the contribution from one motor unit is thus extracted. This "Macro EMG" signal gives information abo...

متن کامل

Aanem Minimonograph Macro Electromyography, an Update

The macro electromyography method was developed in the 1980s. Since then, technical modifications have been made, and a number of conditions have been explored. This study is a methodological introduction and an update of findings in some nerve–muscle disorders. The spike component of a motor unit potential (MUP) recorded by a concentric or monopolar needle electromyography (EMG) electrode is g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 21 2-4  شماره 

صفحات  -

تاریخ انتشار 1987