Calibrator Design for the COBE

نویسندگان

  • J. C. Mather
  • D. J. Fixsen
  • R. A. Shafer
  • C. Mosier
  • D. T. Wilkinson
چکیده

The photometric errors of the external calibrator for the FIRAS instrument on the COBE are smaller than the measurement errors on the cosmic microwave background (CMBR) spectrum (typically 0.02 MJy/sr, 1 σ), and smaller than 0.01% of the peak brightness of the CMBR. The calibrator is a re-entrant cone, shaped like a trumpet mute, made of Eccosorb iron-loaded epoxy. It fills the entire beam of the instrument and is the source of its accuracy. Its known errors are caused by reflections, temperature gradients, and leakage through the material and around the edge. Estimates and limits are given for all known error sources. Improvements in understanding the temperature measurements of the calibrator allow an improved CMBR temperature determination of 2.725±0.002 K. Subject headings: cosmology: Far Infrared background — cosmology: observations

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O ct 1 99 8 Calibrator Design for the COBE 1 Far Infrared Absolute Spectrophotometer ( FIRAS )

(NASA/GSFC) was responsible for the design, development, and operation of the Cosmic Background Explorer (COBE). GSFC was also responsible for the development of the analysis software and for the production of the mission data sets. The COBE program was supported by the Astrophysics Division of NASA's Office of Space Science and Applications. ABSTRACT The photometric errors of the external cali...

متن کامل

Design and calibration of a cryogenic blackbody calibrator at centimeter wavelengths

We describe the design and calibration of an external cryogenic blackbody calibrator used for the first two flights of the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The calibrator consists of a microwave absorber weakly coupled to a superfluid liquid helium bath. Half-wave corrugations viewed 30° off axis reduce the return loss below −35 dB withi...

متن کامل

A Novel Partial Discharge Calibrator Design via Dual Microconroller and High Speed Dac

Insulation is a crucial phenomenon for high voltage apparatus. Partial discharge activity affects the service life of the dielectrics. Therefore partial discharge must be less than a specified value for high voltage equipment. An accurate partial discharge measurement strongly depends on scaling of the measurement systems. It is a general method to use a partial discharge calibrator to calibrat...

متن کامل

Mechanical , Sensor and Control System Design for an Accelerometer Calibrator with One Part Per Million Accuracy

This thesis presents the design and implementation of a low frequency accelerometer calibrator that will be used to calibrate United States Primary Standard Transducers at the U.S. National Bureau of Standards, Gaithersburg Maryland. Accelerometers convert a rate of change of velocity into a measurable quantity, typically voltage, and must be calibrated to find their sensitivity as the ratio of...

متن کامل

Transducer Development and Characterization for Underwater Acoustic Neutrino Detection Calibration

A short bipolar pressure pulse with "pancake" directivity is produced and propagated when an Ultra-High Energy (UHE) neutrino interacts with a nucleus in water. Nowadays, acoustic sensor networks are being deployed in deep seas to detect this phenomenon as a first step toward building a neutrino telescope. In order to study the feasibility of the method, it is critical to have a calibrator that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998