Morphometry of ovarian structures by transrectal ultrasonography in Serrana goats.

نویسندگان

  • J Simões
  • J Potes
  • J Azevedo
  • J C Almeida
  • P Fontes
  • G Baril
  • R Mascarenhas
چکیده

The accuracy of transrectal real-time ultrasonography (RTU) scanning technique to detect ovarian structures (follicles and corpus luteum) of Serrana goats was compared to the data obtained by observation of ovarian sequential slices. This slicing technique (SLI) was considered as reference method. The laparoscopy and laparotomy techniques were also used for corpora lutea identification. For this purpose the ovaries of 14 females were observed, 7-8 days after ovulation, by transrectal ultrasonography followed by laparoscopic examination. Then ovaries were removed and studied by slicing. In the sliced sections of each ovary (n=28), follicles and corpus luteum (CL) were identified and counted. CL and follicular diameters were measured using a millimetre scale. The total number of follicles, counted by RTU, was significantly lower than that observed by SLI (P <0.01). This difference was mainly due to the under estimation of <2 mm follicles category. The correlation coefficient between category data obtained by RTU and SLI methods for the number of follicles > or =3 mm was high (r2=0.95, P <0.001), which highlights the use of UTR as a potential methodology to study the follicular dynamic of goats. There were no significant differences (P >0.05) between the average number (mean +/- S.D.) of corpus luteum identified per ovary by RTU (0.71 +/- 0.75), laparoscopy (0.58 +/- 0.71), laparotomy (0.67 +/- 0.76) or SLI (0.83 +/- 0.76) methods. The accuracy for the identification of ovulation, validated by CL detection on D7-D8 by SLI (100%), was 91.7%, 87.5% and 83.3% by RTU, laparotomy and laparoscopy, respectively. The negative predictive value of RTU, laparotomy and laparoscopy to verify the absence of a CL in the ovary was 81.8%, 75.0% and 69.2%, respectively. The specificity of all three methods for the CL identification was 100%. No significant differences (P >0.05) were found in the probability to detect the exact number of CL (0, 1 or 2) counted in each ovary between the RTU (87.5%), laparotomy (83.3%) and laparoscopy (75.0%) methods when compared with the reference method. The diameter of spherical CL could be estimated with reliability (r2=0.86; P <0.001). The real-time ultrasonographic scanning proved to be a highly accurate method for detection and measurement of several categories of follicles and CL size in Serrana goats. The results of the present study show that laparoscopy and RTU are similarly reliable techniques for CL detection. However, the RTU represents a non-traumatic technique with advantages to animal welfare both in experimental and reproductive evaluation of the size of ovarian structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time of ovulation in nulliparous and multiparous goats.

Fifteen nulliparous and nine multiparous Serrana goats were used, through two successive oestrous cycles, in order to characterize their ovulation time with regard to the number of ovulations after induced and natural oestrus during the breeding season. The onset of oestrus was detected by the amount of vasectomized bucks after oestrus synchronization with prostaglandin, given 10 days apart, an...

متن کامل

Evaluation of Pregnancy Detection in Lori-Bakhtiari Sheep by Transrectal Ultrasonography

Objective: Various practical methods have been used for pregnancy diagnosis in sheep. Methods of pregnancy diagnosis depending on visualization of the conceptus or determination of its secretory products in the maternal blood or in the milk are the most accurate and specific methods for pregnancy. In 1980, B-mode ultrasonography was introduced in the veterinary field and used for pregnancy diag...

متن کامل

Evaluation of Pregnancy Detection in Lori-Bakhtiari Sheep by Transrectal Ultrasonography

Objective: Various practical methods have been used for pregnancy diagnosis in sheep. Methods of pregnancy diagnosis depending on visualization of the conceptus or determination of its secretory products in the maternal blood or in the milk are the most accurate and specific methods for pregnancy. In 1980, B-mode ultrasonography was introduced in the veterinary field and used for pregnancy diag...

متن کامل

Comparison of Transabdominal and Transrectal Ultrasonography of the Prostate Gland in Dogs

Objective- To compare transabdominal (TA) and transrectal (TR) ultrasonography of the prostate gland. Design- Experimental study. Animals- 10 intact male dogs that required euthanasia for reasons other than prostatic disease. Procedures- Prostatic length (L), width (W) and height (H) were measured in T A (L1, W1 and H1) and TR (L2 and H2...

متن کامل

Determination of gestational age in sheep and goats using transrectal ultrasonographic measurement of placentomes.

Three experiments were conducted to determine gestational age in the ewe and doe by measuring placentomes with a B-mode ultrasonograph and a 5 MHz transducer. Transrectal measurements were obtained by placing the female over a bale of hay. In Experiment 1, ewes (n = 12) and does (n = 15) were examined by transrectal ultrasonography every week from breeding to parturition to determine the growth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Animal reproduction science

دوره 85 3-4  شماره 

صفحات  -

تاریخ انتشار 2005